Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 119 of 123
7
Status and Alarm description
Status/Alarm
words
Status/Alarm
bits
Description
Status 0
0
The Lasstec system powered om (Status ON)
1
System initialisation completed
2
Interrogator self-test completed (UC OK)
3
All 4 or 8 sensors are detected present
4
The system is waiting for a Lock or Unlock signal after power on
5
Software version bit 0 (UC type register 1)
6
Software version bit 1 (UC type register 2)
7
Spare
8
Reference detection on weight 1
9
Reference detection on weight 2
10
Reference detection on weight 3
11
Reference detection on weight 4
12
Stabilized weight detected
13
This bit changes at the end of each cycle (life bit)
14
UC measurement is running (all Twistlocks are locked and the system is weihgting)
15
Ready signal (Interrogator ready to measure)
Status 1
0
Input status:
Indicates if the twin-lift system is in twin-lift mode = 1 / if the twin-lift system
is in single-lift mode = 0 (Twinlift down).
1
Input status: Twistlocks are locked
2
Input status: The spreader is landed on a container (Spreader seated)
3
Interrogator mode: 0=Single-Lift / 1=Twin-Lift
4
Input status: The spreader is in the 20ft telescopic position
5
Input status: The spreader is in the 30ft telescopic position
6
Input status: The spreader is in the 35ft telescopic position
7
Input status: The spreader is in the 40ft telescopic position
8
Input status: The spreader is in the 45ft telescopic position
9
Input status: Twistlocks are unlocked (1=unlocked)
10
Bit 0 status container1
11
Bit 1 status container1
12
Bit 0 status container2
13
Bit 1 status container2
14
Ramp adjustment running
15
No acceleration input (stab. Weight)
Status 2
0
SLED setting is OK on TL 1
1
SLED setting is OK on TL 2
2
SLED setting is OK on TL 3
3
SLED setting is OK on TL 4