4.3
DANGERS DUE TO NON-COMPLIANCE
In detail, failure to observe the general danger symbols can result, for example, in the following risks:
/
Failure of important functions of the domestic water station
/
Danger to persons due to electrical and mechanical effects
/
Danger to persons and the environment due to leaks
Refrain from any unsafe working methods.
Failure to comply with these operating instructions and the safety information can not only result in dan-
gers for persons but can also harm the environment and the unit.
4.4
WATER PRESSURE
The water pressure must not exceed 16 bar inlet pressure. In case of a mains pressure above 16 bar (even
temporarily) the domestic water station must not be installed!
4.5
ELECTRICAL DEVICES/EQUIPMENT
Electrical devices/equipment that are not splash-water proof and are situated in the direct vicinity of the
domestic water station may be damaged by water leaking from the domestic water station during back-
washing or caused as a result of the device not being operated in accordance with the manufacturer’s spec-
ifications.
In addition this may also result in short circuits if these electrical devices/equipment being connected to
the electrical power supply.
In the event of such cases persons are at risk and may sustain electrical shocks.
Therefore any electrical devices/equipment situated in the direct vicinity should be splash-water proof, re-
spectively comply with the statutory requirements for wet areas (IP44).
Quantity
Value
Nominal pressure
PN 16
Operating pressure
1.5 - 16 bar (150 - 1600 kPa)
Discharge pressure
1.5 - 6 bar (150 - 600 kPa)
Factory setting: 4 bar (400 kPa)
There must not be any electrical cables and devices underneath or in the immedi-
ate vicinity of the domestic water station!