You must install a 120
Ω
terminator at the end of a CAN
connection (see chapter 6.10, page 46).
If you do not use a Conergy SunReader, leave the sealing
plugs in place on the connector.
6.7
Connecting the 230- V power supply
If you have an inverter with display, you can connect an
external 230-V power supply to the
CTRL
connection (see
Fig. 6-1, page 35, pos.
(4)
). You will then be able to operate
the display of your inverter at any time of day or night.
If you have chosen the combination with the Conergy IPG
easyconnect generator junction box, you will not need an
external power supply, as this is already integrated in the
generator junction box.
If you do not want to connect an external 230-V power
supply, please leave the sealing plugs in place on the
connector.
6.8
Connecting Easyconnect
If you have decided to use the Conergy IPG easyconnect
generator junction box, connect the string inverter to this via
the
CTRL
connection (see Fig. 6-1, page 35, pos.
(4)
) of the
inverter. The CTRL cable is on the back of the generator
junction box. Please see the generator junction box Conergy
IPG easyconnect instruction manual for further information.
Connecting the Conergy SunReader
1. Connect the CAN cable to the
CAN In
connection.
2. Tighten the plug by turning manually.
Connecting the 230- V power supply
1. Plug the 230-V power supply cable supplied into the
CTRL
connection.
2. Tighten the plug by turning manually.
Connecting Easyconnect
1. Connect the CTRL cable to the
CTRL
connection.
2. Tighten the plug by turning manually.