100600B
Conexant
7-1
7
7.0 Parametric Information
7.1 DC Electrical Parameters
DC electrical parameters are specified in
through
Table 7-1. Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Units
Power Supply — Analog
V
AA
, V
BB
4.75
5.00
5.25
V
Power Supply — Digital
V
DD
4.75
5.00
5.25
V
Maximum
∆
|V
DD
– V
AA
|
—
—
—
0.5
V
MUX0, MUX1, MUX2, and MUX3 Input Range
(AC coupling required)
—
0.5
1.00
2.00
V
CIN Amplitude Range (AC coupling required)
—
0.5
1.00
2.00
V
STV, SFM, SML Input Range (AC coupling required)
—
—
0.5
1.00
V
RMS
Ambient Operating Temperature
T
A
0
—
+70
°C