Copyright
©
2022
congatec
AG
HEVAm100
50/54
5
BMC Overview
BMCs are used in servers for remote administration, thereby reducing the need for onsite administration of the servers. Some of the more
common use cases are:
•
power cycling a server
•
monitoring fan speeds and component temperatures
•
monitoring hardware failures
The BMC (Aspeed AST2600) on the conga-HPC/EVAL-Server is for proof of concept only. Carrier board designers can use it as a hardware
design guide or to test the physical interfaces of system firmware (BIOS) or remote system management software. The BMC functionality is
application-specific and not part of the COM-HPC
®
specification
The conga-HPC/EVAL-Server supports HTML5-based browsers for remote monitoring.
5.1
Firmware
Some of the features the BMC firmware support are:
•
KVM/media redirection support via BMC’s video and USB
– redirection with H5View
•
media redirection
– CD redirection
– secure authentication and encryption for remote KVM or H5Viewer
•
remote server power control
– server’s power status report
– support for server power-up, power-down, power cycle, reset and ACPI shutdown
•
IPMI message interface support via communication interfaces such as:
– Keyboard Controller Style (KCS)
– LAN (IPMI over LAN)
– serial interface (access through a serial port. Supports basic and terminal connection modes)
•
IPMI event log and alerting