4. Configuration of C1000
4.1 The Service code
The Service code is used for C1000’s advanced settings such as changing the Master
code, Service code, LED indications and much more. The overview of the settings and
the factory settings can be seen in 4.2
Configuration overview
.
The Service code is
12347890
(factory setting).
Note: Before the Service code can be used the voltage must be turned OFF and
ON (the Service code can now be entered within 10 seconds).
After entering the Service code the reader is in programming mode (the green LED
lights). Each time a setting is made the C1000 goes back to the previous point and the
next setting can be made.
The navigation is by entering the position/ value followed by
#
.
4.2 Configuration overview
Position
Setting
Factory
default
00
Master code (1 til 8 cifre)
4711
01
Service code (1 til 8 cifre)
12347890
02
LED indications
Normal = Yellow, active = Yellow and green
03
Outputs
Output time for 1 and 2 is 5 seconds
04
Special functions
05
Smart reading
06
Background light
08
Backup/cloning the settings
2500
Alle codes on the user positions are deleted
0250
Reset to factory default
4.3 Change the Master code
By default the Master code is
4711
and can only be used to program, change or delete
users on the C1000.
To change the Master code, enter the following:
○
●
○
●
●
○
○
●
○
#
Key in the
Service code
#
Key in
00
#
Key in a new
code or show tag