4. Configuration of C1000

4.1 The Service code

The Service code is used for C1000’s advanced settings such as changing the Master 

code, Service code, LED indications and much more. The overview of the settings and 

the factory settings can be seen in 4.2 

Configuration overview

.

The Service code is 

12347890

 (factory setting).

Note: Before the Service code can be used the voltage must be turned OFF and 

ON (the Service code can now be entered within 10 seconds).

After entering the Service code the reader is in programming mode (the green LED 

lights). Each time a setting is made the C1000 goes back to the previous point and the 

next setting can be made.

The navigation is by entering the position/ value followed by 

#

.

4.2 Configuration overview

Position 

Setting 

   Factory 

default

00 

 

Master code (1 til 8 cifre) 

4711

01 

 

Service code (1 til 8 cifre) 

12347890

02 

 

LED indications   

 

Normal = Yellow, active = Yellow and green

03 

 

Outputs 

 

 

 

Output time for 1 and 2 is 5 seconds

04 

 

Special functions

05 

 

Smart reading

06 

 

Background light

08 

 

Backup/cloning the settings

2500   

Alle codes on the user positions are deleted

0250   

Reset to factory default

4.3 Change the Master code

By default the Master code is 

4711

 and can only be used to program, change or delete 

users on the C1000.

To change the Master code, enter the following:

○ 

 ○

 

 ○

○ 

 ○

#

Key in the

Service code

#

Key in

00

#

Key in a new 

code or show tag

Summary of Contents for 480000

Page 1: ...Codetastatur C1000 Mykey Art Nr 480000 sort 480001 hvid Classic Art Nr 482000 sort 482001 hvid User manual C1000_usermanual_ENGjan20...

Page 2: ...iguration of C1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Blocking 6 Manual reset 7 T...

Page 3: ...Service code 2 Installation Mount the reader on a even surface use the following drill template for precise fit ting Connect the wires to power supply door strike assembly board etc Colour scheme Red...

Page 4: ...utput 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indication No light Li...

Page 5: ...oggles the output Ie the code is entered to unlock the door and entered to lock it again Programming the same user 3 times By programming the same code on the same position 3 times the output is desig...

Page 6: ...s Key in a position and it counts automatically to the next position Codes can be programmed alternatively as you see fit For more codes tags repeat from here Note This programming mode overwrites exi...

Page 7: ...00 goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master c...

Page 8: ...normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press gr...

Page 9: ...nds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions By fac...

Page 10: ...codes and Mifare tags only activate output 2 High Security High Security increases the C1000 s security by ensuring 2 positions have to be activat ed before the output is activated the positions must...

Page 11: ...lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The C1000 is now reset to factory default and the user codes tags are deleted 7 Technical specifications Volt...

Page 12: ...ED 0V active External controlling red LED 0V active CT 2000 Prox ALARM SYSTEM A S Prox 1 3 5 7 9 2 4 6 8 0 0V GND Doorstrike 12V DC 12V DC 0V GND Doorstrike 12V DC 12V DC 12V DC 0V DC REX 0V active Hi...

Reviews: