5. Backup card
The CM1000’s informations can be saved and loaded with a Backup card (Art. No.:
480080).
Please view the following configuration scheme for further information.
6. Blocking
The CM1000 is blocked for 1 minute after 4 incorrect codes/Mifare tags.
LED indication:
*
*
7. Manual reset
The CM1000 can be reset to factoty default manually.
• Turn the voltage off.
• Connect the yellow and brown wire.
• Turn the voltage on (9 - 25 VDC) the readers LED’s lights and the buzzer sounds.
• Turn the voltage off and disconnect the yellow and brown wire.
The CM1000 is now reset to factory default and the user codes/tags are deleted.
8. Technical specifications
Voltage:
12 VDC, 30 mA
Voltage range:
9 - 25 VDC
Mifare reading:
Max. 50 mm
Output:
2x open collector, max. 500 mA
Input:
External buzzer/High Security (brown) and REX, 0V active (blue)
Protection rate:
IP67
Color:
Black or white
Cable:
2,5 m white, 8 cores
Dimensions (HxWxD): Mykey = 76x49x8 mm / Classic =130x50x8 mm
11