Mimic – NVIDIA® Jetson AGX Xavier™ to Jetson™ TX2/TX2i/TX1
Adapter
Users Guide
Document: CTIM-00502
Revision: 0.00
Page 12 of 16
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2019-03-12
S2 DIP Switch – Misc. Control Switch
Function
Miscellaneous Control
Location
S2
Pinout
Switch
Function
Description
ON
OFF
S2A
CSI x2/x4
– selects CSI5
or CSI6 depending if you
are using 2-lane or 4-lane
CSI cameras
2-lane CSI
for CSI6 from
module
4-lane CSI
for CSI5 from
module
S2B
FORCE PWR
– forces the
CARRIER_PWR_ON
signal from the module
Force carrier
power on
Normal
Operation
S2C
AUTO-ON
– selects
whether to power on
when power is applied or
require a push button
event
Auto-on
when power
applied
Push button
event
required
S2D
FRC PRSNT
– forces the
module present signal to
be asserted
Assert the
module
present
signal
Normal
Operation