Cables and Cable Kit information
The following table summarizes the Sprocket Carrier cables and cable kit information available.
All the cable are avaible as a la carte items. However, two starter cable kits,deemed to be bare minumum that a
customer would need to get started, are also available: CKG046 (inlcudes 1 x MSG069 and 1x CBG251) is
intended for North American customers; while CKG048 (inlcudes 1 x MSG073 and 1x CBG251) is intended
for customers outside North America. Please refer to notes in ‘Power Input’ section for important details.
Drawing
No.
Part No.
Description
ASG008
North America
Starter Cable kit
(CKG046)
ASG008
Multi-region
Starter Cable kit
(CKG048)
-
MSG069
12V North America Power Adapter to
PicoBlade Kit
1
-
-
MSG073
12V Multi-Region Power Adapter to PicoBlade
Kit
-
1
-
CBG251
IO Cable with Flying Leads
1
1
-
CBG252
4 pin Molex Picoblade Cable to Flying Leads
-
-
CBG254
Micro USB to USB Type-A Female (For Host) -
-
-
CBG247
Micro USB to USB Type-A Male (For
OTG/Programming)
-
-
-
XHG301
TX2/TX1 Passive Heat Sink
-
-
3
rd
Party Accessories
Part Number
Manufacturer
Description
FAW-1233-03
Leopard Imaging Inc
Micro Coax I-PEX Cable: 300mm, MIPI Camera Cable
LI-IMX274-MIPI-CS
Leopard Imaging Inc
Sony IMX274 4K MIPI Interface camera module with CS
Mount lens (Datasheet Link)
LI-IMX185-MIPI-CS
Leopard Imaging Inc
Sony IMX185 MIPI Interface camera module with CS Mount
lens (Datasheet Link)
Please note a USB to USB Type-A Male cable would be required to flash the module, if customer does not
have this available, CBG247 can be ordered.
Furthermore, some customers may require some TTL 3V3 to USB tool like BusPirate to connect TTL signals
from Sprocket to USB port of your computer in order to acess console (Uart0). Sprocket has been tested with
Bus Pirate v3.6.
Alternatively, TTL to USB cable like TTL-232R-3V3-WE or similar could be used. For more information on
this, please refer to the ‘Note’ on page 17 under ‘Typical Installation’ section.