20 RS-232/RS-485/422
Option
Xtreme/104 Opto User's Manual, ver. 0.00
Full Duplex Mode
By making sure that there are no jumpers on positions A and C of
jumper blocks JB4, JB5, JB6 and JB7 you can run the individual
RS-485/422 ports in full duplex mode. In this mode, TxD & RxD
are active all the time. This mode is typically used in point to
point situations much like RS-232.
Figure 1
shows the locations of jumper block JB4, JB5, JB6, JB7
and J1, J2.
Example
The example below shows the settings on JB4, JB5, JB6, and
J1, J2 where RS-485 ports 1, 2 and 3 are set for full duplex
mode. Port 4 is RS-232 and therefore is not set for full duplex
JB4
A
JB5
B
C
D
E
F
G
A
B
C
D
E
F
G
JB6
A
B
C
D
E
F
G
JB7
A
B
C
D
E
F
G
J1
Jumper is
off J1
J2
Jumper is
off J2
Technical Note:
J1 controls ports 1 and 2 and J2 controls ports 3 and 4. If both
ports 1 and 2 are set for full duplex then J1 should not be
jumpered. If both ports 3 and 4 are set for full duplex then J2
should not be jumpered.