background image

Connect Tech Xtreme/104 User’s Manual 

14                                                                                                                     Revision 0.05 

Software Installation 

Xtreme/104 adapters are standard multi-port serial adapters that utilize 16C654 quad UARTS.  
In many cases, users have software that will interface directly to the Xtreme/104 adapters.  Many 
operating systems come with handlers to control access to multiple 16550 style UARTS.  If you 
require further information please contact Connect Tech 

Customer Support

 

Technical Tips: 
Your Xtreme/104 adapter may ship with a CD that includes 

howto.txt

 or 

readme.txt

 files.  Please examine these files for 

technical tips or release notes concerning installation and 
configuration of various device drivers and software utilities. 
 
If you did not receive a driver diskette or CD for your operating 
system or you require additional information, please go to the 

Download Zone

 of the 

Support Center

 on the 

Connect Tech

 

website for product manuals, installation guides, diagnostic 
utilities and device driver software. 

 

Summary of Contents for Xtreme/104 Opto

Page 1: ...buy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of th...

Page 2: ...Serial Communications User Manual Connect Tech Inc 42 Arrow Road Guelph Ontario N1K 1S6 Tel 519 836 1291 Toll 800 426 8979 North America only Fax 519 836 4878 Email sales connecttech com support connecttech com URL www connecttech com CTIM 00003 Revision 0 05 October 6 2004 ...

Page 3: ...ech Inc reserves the right to substitute an equivalent product if available or to retract Life Time Warranty if no replacement is available The above warranty is the only warranty authorized by Connect Tech Inc Under no circumstances will Connect Tech Inc be liable in any way for any damages including any lost profits lost savings or other incidental or consequential damages arising out of the use...

Page 4: ...ed into a device ultimately subject to FCC DOC IC and CE certification The customer is responsible for bringing the completed device into compliance prior to resale Connect Tech has designed the Xtreme 104 Xtreme 104 RS 232 with EMI and EMC considerations such as Ground and power planes Controlled slew rate signals EMI EMC reducing PCB layout ...

Page 5: ... 2 two IRQs 12 Mode 3 two IRQs 12 Baud Rate Selection 13 Software Installation 14 Specifications 15 Operating Environment 15 Power Requirements 15 PC Bus Interface 15 Communications 15 UARTs 15 RS 232 Xtreme 104 Xtreme 104 RS 232 15 RS 422 485 Xtreme 104 15 Control Signals 15 Dimensions 16 Connectors Interface 16 Part Numbers 16 Xtreme 104 four port model 16 Xtreme 104 eight port model 16 Xtreme 1...

Page 6: ...te selection 13 Figure 6 Example of electrical interface selection 20 Figure 7 Example of half duplex setting 20 Figure 8 Example of line termination setting 21 Figure 9 RS 422 485 wiring diagram 4 wire 22 Figure 10 RS 422 485 wiring diagram 2 wire 22 List of Tables Table 1 Port Address Settings 11 Table 2 Baud rates 13 Table 3 HD1 HD2 P1 P2 40 pin port header pinouts 17 Table 4 DB 9 cable connect...

Page 7: ...rier You may contact us by letter at Connect Tech Inc Technical Support 42 Arrow Road Guelph Ontario Canada N1K 1S6 Email Internet You may contact us through the Internet Our email and URL addresses on the Internet are sales connecttech com support connecttech com www connecttech com Note Please go to the Download Zone or the Knowledge Database in the Support Center on the Connect Tech website for...

Page 8: ...eme 104 RS 232 adapters may reside in a system 16C654 quad UARTs control each port The 16C654 quad UART has 64 byte TxD and RxD FIFO buffers for each port and automatic software hardware flow control Each port has independent baud rate selection offering baud rates from 50 230 4 Kbps RS 232 and 50 460 8 Kbps RS 422 485 with 5 6 7 or 8 data bits and 1 1 5 2 stop bits odd or even parity On board jum...

Page 9: ...ators Select jumper block RS 232 enable jumper block ports 1 to 4 16C654 Quad UART Pin 1 Pin 40 Xtreme 104 eight port model J1 J4 J5 J6 J2 J3 C D 3 4 7 9 5 6 10 11 12 14 15 A B HD1 HD2 IRQ jumper block PC 104 bus connector IRQ jumper block Ports 1 to 4 40 pin connector Ports 5 to 8 40 pin connector Extreme 8 104 only Half Duplex Select jumper block I O address IRQ Mode Clock Select jumper block Tx...

Page 10: ...k Ports 1 to 4 40 pin connector I O address IRQ Mode Clock Select jumper block 16C654 Quad UART JB1 Pin 1 Pin 40 Xtreme 104 RS 232 eight port model JB2 JB3 D C 9 7 4 3 6 5 10 11 12 14 15 A B P2 P1 IRQ jumper block PC 104 bus connector IRQ jumper block Ports 1 to 4 40 pin connector Ports 5 to 8 40 pin connector I O address IRQ Mode Clock Select jumper block 16C654 Quad UART 16C654 Quad UART Pin 1 P...

Page 11: ...red with the jumper block J1 or JB1 on the Xtreme 104 or Xtreme 104 RS 232 adapter respectively Jumpers 0 1 and 2 select a set of port addresses for the ports Status Port Addresses Some operating system device drivers can utilize an Interrupt Status Port for example Windows NT offers it as an option and for SCO Unix it is mandatory This can improve your system s efficiency The Xtreme 104 and Xtrem...

Page 12: ...ddress jumper block set for port addresses 100 108 110 118 120 128 130 138 hex and status port 140 hex enabled J1 or JB1 0 1 2 I O address select Status port enable 3 4 5 6 7 I O address select I O address select Position 7 is not available on the Xtreme 104 232 J1 or JB1 0 1 2 I O address select Status port enable 3 4 5 6 7 I O address select I O address select Position 7 is not available on the ...

Page 13: ...n IRQ 4 J1 0 1 2 IRQ mode select 3 4 5 6 7 C D 3 4 7 9 5 6 IRQ jumper block Xtreme 104 IRQ mode select JB1 0 1 2 IRQ mode select 3 4 5 6 A B 9 7 4 3 6 5 IRQ jumper block Xtreme 104 232 IRQ mode select Example Mode 2 two IRQs The following example shows the settings on J1 or JB1 and the IRQ jumper blocks so that ports 1 3 5 7 will interrupt on IRQ 7 and ports 2 4 6 8 will interrupt on IRQ 12 J1 0 1...

Page 14: ...ease refer to Table 2 for a list of standard and extended baud rates for the Xtreme 104 and Xtreme 104 RS 232 Figure 5 Example of baud rate selection Example I O address IRQ Clock Select jumper block J1 JB1 0 1 2 Clock select 3 4 5 6 7 jumper installed 460 8 KBPS max RS 230 4 KBPS max RS jumper not installed 115 2 KBPS max Position 7 is not av ailable on the Xtreme 104 232 Table 2 Baud rates Stand...

Page 15: ...n please contact Connect Tech Customer Support Technical Tips Your Xtreme 104 adapter may ship with a CD that includes howto txt or readme txt files Please examine these files for technical tips or release notes concerning installation and configuration of various device drivers and software utilities If you did not receive a driver diskette or CD for your operating system or you require additiona...

Page 16: ...connector Communications UARTs 16C654 quad UARTs communication controllers On chip 64 byte TxD and RxD FIFO buffers per port Automatic RTS CTS Hardware flow control Automatic XON XOFF Software flow control Compatible with 16550 style software drivers RS 232 Xtreme 104 Xtreme 104 RS 232 Programmable baud rate generator up to 230 4 8 Kbps on all RS 232 ports Full duplex point to point RS 422 485 Xtr...

Page 17: ...0 pin header connectors Xtreme 104 Xtreme 104 RS 232 eight port models Two 40 pin header connectors Part Numbers Xtreme 104 four port model 1040490001 Xtreme 104 4 ports 16C654 UARTs with cable Xtreme 104 eight port model 1040890001 Xtreme 104 8 ports 16C654 UARTs with cable Xtreme 104 RS 232 four port model 1040400001 Xtreme 104 4 port RS 232 16C654 UARTs with cable Xtreme 104 RS 232 eight port m...

Page 18: ...put 2 or 6 18 RI input RTS output 2 or 6 19 SG signal gnd SR signal reference 2 or 6 20 N C N C N C N C 3 or 7 21 DCD input RxD input 3 or 7 22 DSR input CTS input 3 or 7 23 RxD input RxD input 3 or 7 24 RTS output RTS output 3 or 7 25 TxD output TxD output 3 or 7 26 CTS input CTS input 3 or 7 27 DTR output TxD output 3 or 7 28 RI input RTS output 3 or 7 29 SG signal gnd SR signal reference 3 or 7...

Page 19: ...8 10 9 7 5 3 Printed circuit board 2 1 14 16 18 20 19 17 15 13 12 11 24 26 28 30 29 27 25 23 22 21 34 36 38 40 39 37 35 33 32 31 View facing 40 pin connector Part Number CAB8104 Technical Tip The red stripe on the CAB8104 cable indicates pin 1 on the 40 pin header connector Please ensure that you terminate the DCD or CTS signals if your application does not use them The common way to do this is to...

Page 20: ...d rate of 115 2 Kbps position 6 not jumpered IRQs 1 J1 or JB1 set for all ports interrupting on a single interrupt positions 3 4 not jumpered 2 AB and CD blocks set for no interrupts all positions not jumpered Electrical Interface J2 and J3 set for all ports RS 422 485 all positions not jumpered Xtreme 104 adapters only Half Duplex J4 set for all ports running in full duplex mode all positions not...

Page 21: ...d ports 5 6 7 8 are set for RS 422 485 RS 232 Enable jumper blocks J2 J3 P1 P2 P3 P4 P8 P7 P6 P5 RS 232 Enable jumper blocks J2 J3 P1 P2 P3 P4 P8 P7 P6 P5 Technical Note You can set up the RS 232 serial ports to run at up to 230 4 Kbps but you must use good quality serial cables with lengths that do not exceed 2 metres Half Duplex RS 422 485 You can set jumper block J4 to run individual RS 422 485...

Page 22: ... fixed resistors Please refer to Figure 1 for the location of J5 and J6 Figure 8 Example of line termination setting Example The following example shows the settings on J5 and J6 where RS 422 485 ports 5 6 7 8 are terminated Ports 1 2 3 4 are RS 232 and therefore should no be terminated with resistors J5 RX Tx and Rx Terminators 120 Ω J6 P4 TX RX TX RX TX RX TX P3 P2 P1 TX P5 RX TX RX TX RX TX RX ...

Page 23: ...R SR Xtreme 104 adapter RS 422 485 peripheral 3 4 2 5 6 9 7 8 1 Figure 10 depicts a 2 wire cabling scheme between a port on the Xtreme 104 adapter to a port on the RS 422 485 peripheral Figure 10 RS 422 485 wiring diagram 2 wire RTS RTS CTS CTS TxD TxD RxD RxD RxD TxD RxD TxD RTS CTS RTS CTS SR SR Xtreme 104 adapter RS 422 485 peripheral 3 1 4 2 5 6 9 7 8 Technical Tip The RS 422 485 electrical in...

Page 24: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...