Uplink: Payload description
Example
UL Message:
0x
2C
026F
34
005e
010f
00b5
BYTE BIT TYPE
NAME
DESCRIPTION
0
0-1 UInt2
Reserved
Reserved
0
2
Boolean Transmit power Full power mode. 1= TRUE, 0 = FALSE
0
3
Boolean Power Control
Active power control. 1= On, 0 = OFF
0
4-7 UInt4
FW version
FW version
1-2
0-15 UInt16 Temperature
(Value /10) - 40 = Temperature [°C]
(Value /18) - 8 = Temperature [°F]
3
0-7 UInt8
Humidity
Humidity [%]
4-5
0-15 UInt16 PM1.0
Mass concentration [ug/m3]
6-7
0-15 UInt16 PM2.5
Mass concentration [ug/m3]
8-9
0-15 UInt16 PM10
Mass concentration [ug/m3]
0x2C = 00101100Bin
Full power = TRUE
Active power control = On
FW Version = 2
Header
0x026F = 623Dec ->
(623/10)-40 = 22,3 °C
Temperature
0x34 = 52Dec ->
52%
Humidity
0x005e = 94Dec ->
94 ug/m3
PM1.0
0x010f = 271Dec ->
271 ug/m3
PM2.5
0x00b5 = 181Dec ->
181 ug/m3
PM10