background image

Downlink

14

• Settings of the device can be updated with the downlink message
• Device requests new settings approximately every 24 hours
• You must be very careful when you update the settings

• settings affect both the subscription and the battery life of the device!

• Downlink message is optional

• If  any  downlink  message  is  not  received,  device  continues  with  the

current settings

• Detection  interval  and  how  often  messages  are  sent  when  the  space  is

available or occupied can be adjusted with the settings

• Default settings when device has not been configured with downlink:

• Default activity reporting period is 22minutes
• When  the  space  is  occupied,  a  message  is  sent  after  every  activity

period with updated counter values

• When  the  space  becomes  available  the  status  will  be  sent  after

Inactivity Detection Period. The default value is 15minutes.

• After  inactivity  message  has  been  sent,  the  device  goes  to  Inactivity

mode:  when  activity  is  detected,  status  message  will  be  sent
immediately with counters increased and activity mode starts

• Default inactivity reporting period is about eight hours
• After inactivity period has expired without activity detected, the status

message is sent without counters increased and new inactivity period
starts

• If the power control feature is set on, the device will automatically adjust the

transmit power to optimum level to save battery and create less unnecessary
interference to radio network

• By default power control is OFF

Summary of Contents for Detectify R3.2

Page 1: ...ns com User Manual Connected Detectify R3 2 Detectify Connected Detectify is a motion detector for indoor purposes based on a passive infrared technology sensor with a detection area of up to 5 meters Last updated July 2020 ...

Page 2: ...3 5 Using this manual Read me first About the device Function Assembling and Installation Uplink Payload description Downlink Downlink Payload Description Troubleshooting Technical Specification 7 9 12 14 15 17 18 2 ...

Page 3: ...l and all safety instructions to ensure safe and proper use The descriptions in this manual are based on the default settings of your device The images used in this manual may differ from the actual product The contents of this manual may differ from software provided by service providers or carriers and are subject to change without prior notice Access the Connected Inventions website www connected...

Page 4: ...nual for future reference In case of malfunction deliver the device to the supplier Do not open the cover Do not remove packing material and do not repack the device unless necessary Contact the shipping agent before transportation Inside the device there is a battery which contains approximately 1 4 g of lithium Return the device to a disposal station which collects electronics waste and batterie...

Page 5: ...mal usage running default settings the batteries will last up to five years There are two different versions of the device 90 degree wide detection angle version see picture below for sensing motion in rooms and 30 degree narrow detection angle version see picture below for more restricted areas like work desks The device can be used for alerting immediately about movement in space as well as counti...

Page 6: ...90 degree wide detection angle for sensing motion in rooms 30 degree narrow detection angle for more restricted areas 6 ...

Page 7: ...rs accordingly After Activity Reporting Period ARP has been reached the device will send a message with incremented counters and starts a new Activity Reporting Period Still in Activity Mode in case no movement was detected until Inactivity Detection period IDP was reached the last movement counters are sent and the device goes to Inactivity mode Once Inactivity Reporting Period IRP has passed wit...

Page 8: ...8 State transition example where inactivity report has activity count 0 State transition example where inactivity report has activity count 0 ...

Page 9: ... on the bottom of the device You can also read the identifier and the PAC key using the QR code The picture below is an example of a label Use a small screwdriver to slide the power switch to I position Please note that the switch should slide relatively effortlessly 1 2 Do not use excess force to slide the switch On ...

Page 10: ... 90 degrees depending on the version You can use direct screw plate included or angle joint support included for attaching the device to surface Please note Avoid placing device closer than 15cm from any metal or magnetic object electric cables electric devices or selective glass as this will dramatically reduce radio performance as well as battery life of the device ...

Page 11: ...device locks into place For work desk installation make sure the hinge of the screw plate is pointing to metal support structure if any Attach the device to screw plate pins so that the antenna is pointing away from metal structure and twist gently clockwise until device locks in place Avoid placing the antenna closer than 15cm from any metal objects Antenna Antenna ...

Page 12: ...E DESCRIPTION 0 0 Reserved 0 1 boolean Activity update 0 2 boolean Full TX power mode 0 off 1 on 0 3 boolean Power control 0 off 1 on 0 4 7 UINT4 Version 1 2 0 15 UINT16 Activity count 3 6 0 32 UINT32 Cumulative activity count 7 11 Reserved 12 ...

Page 13: ...Uplink message example 0x2d00010000257 Version 2 Power control On Full TX power mode On Activity update false Activity count 1 Cumulative activity count 599 13 ...

Page 14: ...ce is occupied a message is sent after every activity period with updated counter values When the space becomes available the status will be sent after Inactivity Detection Period The default value is 15minutes After inactivity message has been sent the device goes to Inactivity mode when activity is detected status message will be sent immediately with counters increased and activity mode starts ...

Page 15: ... 0 boolean Power control reconfigure 0 1 boolean Power control on 0 2 7 Reserved 1 0 7 UINT8 Activity Reporting Period 1 n 5min30sec 2 0 7 UINT8 Inactivity Reporting Period 1 n 5min30sec 3 0 7 UINT8 Inactivity Detection Period 1 n 5min30sec 4 7 Reserved set to 0 ...

Page 16: ...od 3 1 3 5min30sec 22min Inactivity reporting period 53 1 53 5min30sec 5hours Inactivity detection period 0 1 0 5min30sec 5min30sec Make sure the new settings are valid before applying them In case the new settings are not valid or the DL message is not received the device will continue working with the current settings ...

Page 17: ...erground location and other obstacles can dramatically reduce radio signal Check the operation mode of the device Incorrect downlink configuration will affect the behaviour of the product Ensure the configuration is properly done connectedfinland connected_fin connectedinventions www connectedinventions com 358 103115800 Connected Inventions Spektri Business Park Kvintti Building Metsänneidonkuja 12 02...

Page 18: ...luding batteries IP20 2 x AA 3 6V 5 400 mAh 5 years when the device sends approximately 24 messages a day Nysenba PIR Sensor HM312 Temperature 0 50 C Humidity 0 95 Sigfox 868 MHz RCZ1 902 MHz RCZ2 920 MHz RCZ4 Internal helical antenna Uplink Downlink FCC CE Sigfox Class 0U P_010A_C70F_01 P_010A_3530_01 P_010A_1CC1_01 Narrow Beam Wide Beam CIDTY 3009 R0302 RCZ1 CIDTY 3015 R0302 RCZ1 CIDTY 3209 R030...

Reviews: