DX-1S Digital PABX - Programming Manual
5-33
5.6.14 PROGRAMMING ITEM 96 : FAST FLASH ONLY
This item is to program the extension if the extension is connected a 100ms flash telephone. If this option
is enabled, system will accept flash of 50ms to 200ms. If on hook time is more than 300ms, system will
disconnect the call.
It is recommended for telephone having flash timing of 50ms to 200ms to enable this option. It will
increase the operation efficiency and avoid false flash.
Command
3 * 96 * Index1 * Value <Enter> or
3 * 96 * Index1 * Value * Index2 <Enter>
where Index1 = 1 ~ 239 : extension number
Index2 = 1 ~ 239 : extension number <Optional>
Value = 0 : disable
Value = 1 : enable
Condition
1.
When Fast Flash Only is enabled, the flash and on hook timing of the extension is fixed and is
independent of Programming Item 21 & 22 - Minimum & Maximum Flash Time.
2.
Only DTMF telephone can use this option.
Default Value
Default = 0 (disable)