DX-1S Digital PABX - Programming Manual
7-2
7.2 SYSTEM PROGRAMMING RECORDS
Item
No.
Description
Command
Record
(Default Value)
0
Page Port Service Status
3 * 0 * Value <Enter>
Value = 1 : enable, 0 : disable
(1)
1
Two Trunk Conference Status
3 * 1 * Value <Enter>
Value = 1 : enable, 0 : disable
(1)
2
Call Override Status
3 * 2 * Value <Enter>
Value = 1 : enable, 0 : disable
(1)
3
Indication Of Call Waiting Status
3 * 3 * Value <Enter>
Value = 1 : enable, 0 : disable
(1)
4
Busy Tone Type
3 * 4 * Value <Enter>
0 = (0.35s on + 0.35s off)
(0)
5
Ringing Tone Type
3 * 5 * Value <Enter>
0 = (1s on + 4s off)
(0)
6
Feature Activation Dial Tone Type
3 * 6 * Value <Enter>
0 = (0.4s on + 0.05s off)
(0)
7
Confirmation Tone Type
3 * 7 * Value <Enter>
0 = two burst of (0.2s on + 0.2s off)
(0)
8
Call Waiting Tone Type
3 * 8 * Value <Enter>
0 = (0.4s on + 4s off)
(0)
9
Incoming Trunk Ringing Type
3 * 9 * Value <Enter>
0 = (0.4s on + 0.2s off + 0.4s on + 0.4s off)
(0)
10
Call Hold Music Type
3 * 10 * Value <Enter>
Value = 0 : Internal music, 1 : External music
(0)
11
Wake Up Service Message Type
3 * 11 * Value <Enter>
Value = 0 : Internal music, 1 : External music
(0)
12
Dialing Tone Timeout
3 * 12 * Value <Enter>
Value = 1 ~ 255 (seconds)
(10)
13
Busy Tone Timeout
3 * 13 * Value <Enter>
Value = 1 ~ 255 (seconds)
(10)
14
Interdigit Timeout
3 * 14 * Value <Enter>
Value = 1 ~ 255 (seconds)
(5)
15
No Answer Timeout
3 * 15 * Value <Enter>
Value = 1 ~ 255 (seconds)
(15)
16
Ringing Timeout
3 * 16 * Value <Enter>
Value = 1 ~ 255 (seconds)
(30)
17
DISA Dialing Timeout
3 * 17 * Value <Enter>
Value = 1 ~ 25 (seconds)
(10)
18
Call Back Timeout
3 * 18 * Value <Enter>
Value = 1 ~ 100 (10 ~ 1000 seconds)
(30)
19
Call Hold Timeout
3 * 19 * Value <Enter>
Value = 1 ~ 100 (10 ~ 1000 seconds)
(10)
20
Automatic Call Back Ringing Timeout
3 * 20 * Value <Enter>
Value = 1 ~ 255 (seconds)
(15)
21
Minimum Flash Time
3 * 21 * Value <Enter>
Value = 2 ~ 9 (0.2 ~ 0.9 seconds)
(2)
22
Maximum Flash Time
3 * 22 * Value <Enter>
Value = 3 ~ 10 (0.3 ~ 1 seconds)
(8)
23
Door Lock Relay On Time
3 * 23 * Value <Enter>
Value = 1 ~ 25 (seconds)
(1)
24
Trunk Make/Break Ratio
3 * 24 * Value <Enter>
0 = 40/60 make/break ratio
1 = 33/67 make/break ratio
(0)
25
Trunk Flash Time
3 * 25 * Value <Enter>
Value = 1 ~ 9 (0.1 ~ 0.9 seconds)
(5)
26
DTMF Dialing Tone Time
3 * 26 * Value <Enter>
Value = 1 ~ 5 (0.1 ~ 0.5 seconds)
(2)
27
DTMF Dialing Interdigit Time
3 * 27 * Value <Enter>
Value = 1 ~ 5 (0.1 ~ 0.5 seconds)
(2)
28
Trunk Dialing Timeout A
3 * 28 * Value <Enter>
Value = 1 ~ 255 (seconds)
(25)