background image

Fine Cooking Equipment For Over 70 Years

1. Preparation For Installation:

Z223.1

Installation must be made by a licensed plumber.

2. Clearances And Ventilation:

Safe and satisfactory operation of the griddle depends, to a great

extent, upon it’s proper installation. It should be installed in accordance with the National Fuel
Gas Code

, these instructions, and applicable State and Local Codes.

A gas pressure regulator is supplied with your griddle. The regulator must be installed before
connecting griddle to gas supply line.

The griddle and it’s individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45
kPa).

The griddle must be isolated from the gas supply piping system by closing it’s individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.45 kPa).

This griddle is designed for installation in non-combustible locations

only with 4” clearance from sides and 6” clearance from back.

Please note: air vent can plug with grease, thereby shutting

gas supply off. Install regulator in a drip-free area.

Installation,

Operation &

Maintenance

Instructions

CEG SERIES THERMOSTATIC GRIDDLES

For Your Safety

Do NOT store or use gasoline or
other flammable vapors and
liquids in the vicinity of this, or
any other equipment.

Warning!

Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or
death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing
this equipment.

To Purchaser

After installation of your griddle, immediately contact your local gas supplier to obtain
information in the event the user of your equipment smells gas. This information must be
posted in a prominent location.

To User

Upon receipt of this griddle, inspect it thoroughly for any damage which may have occurred
during shipment. If damage is observed, contact the delivery agency immediately.

RETAIN THIS MANUAL FOR FUTURE USE

The Connerton Company

1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145

Telephone: (714) 547-9218   Fax: (714) 547-1969

www.connertoncompany.com

Reviews: