background image

GARAGE DOOR

OPERATOR

USER’S MANUAL

FULLY INSULATED GARAGE DOOR SYSTEMS

TM

Model: FBC200 

Summary of Contents for FBC120

Page 1: ...GARAGEDOOR OPERATOR USER SMANUAL FULLY INSULATED GARAGE DOORSYSTEMS TM Model FBC200...

Page 2: ...R OPERATOR USER GARAGE DOOR OPERATOR USER S MANUAL S MANUAL S MANUAL S MANUAL Model FBC200 WARNING ONLY QUALIFIED AND EXPERIENCED TECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERW...

Page 3: ...ER S MANUAL 2 OUTLINE 1 Safety instructions 3 2 Main features 3 3 Technical specifications 4 4 Check 4 5 Installation and adjustment 5 6 Programming 9 7 External terminal connections 15 8 Maintenance...

Page 4: ...ould only be operated when it can be observed to avoid accidents Install and adjust the manual release so that the handle hangs less than 1 5m above the floor Our company reserves the right to change...

Page 5: ...BC180 FBC200 FBC220 Motor power 60 W 80 W 100 W 120 W Lifting capacity 600 N 800 N 1000 N 1200 N Max door size 10 m 2 12 m 2 14 m 2 16 m 2 Power supply 220X 1 10 V AC 50 60Hz Motor 24VDC Ambient tempe...

Page 6: ...rage door and observe the highest point of door while moving Close the door again and mark this highest point on the wall mark a horizontal line across the vertical centerline around 40mm above the hi...

Page 7: ...he release arm on the shuttle towards the power head Fasten the four screws M6x22mm Straight arm Pin and R pin x1 M6x22mm Screw x4 The release arm towards the powerhead Fig 5 Step 3 Place the power he...

Page 8: ...end of the rail up to the header bracket that has been mounted above the garage door insert the bolt and secure it with nut see Fig 7 Header bracket Bolt and nut M8 Expansion bolt Not included in acce...

Page 9: ...arm to the door bracket with pin and R pin Link the straight arm to the shuttle with pin and R pin then connect L arm to straight arm with two screws M8X16 and screw caps M8 ensure the door arm can be...

Page 10: ...manually To reconnect the door move the door by hand until it engages into the chain shuttle 6 Programming SET button Mode set and Confirm function CODE button Transmitter code set and clear function...

Page 11: ...as been programmed the gate will open stop close or stop cycle Button 4 LOCK button Button 1 Button 2 Button 4 Button 3 Fig 13 Adding extra transmitter learn 1 Press the CODE Su is indicated on the LE...

Page 12: ...n and Close limit 1 Press and hold SET four seconds until P1 is indicated on the LED display The operator is now in programming mode 2 Press SET again OP is indicated on the LED display 3 Press and ho...

Page 13: ...f the door meets an obstruction during closing it will stop and reverse about 15cm 20cm 1 Press and hold SET four seconds until P1 is indicated on the LED display 2 Press UP button P2 is indicated on...

Page 14: ...s indicated on the LED display 2 Press UP button twice until P3 is indicated on the LED display 3 Press the SET The factory preset is H0 4 Press UP H1 will display to enable the photocell Press DOWN H...

Page 15: ...ned position DOWN UP SET CODE CODE SET UP DOWN DOWN UP SET CODE 1 2 3 4 CODE SET UP DOWN DOWN UP SET CODE 5 Increase time Decrease time Fig 19 Door lock mode 1 Press and hold SET four seconds until P1...

Page 16: ...PB J 9 T2 T1 F1 AC24V IN LAMP Infrared photocell Button switch Motor Lamp Transformer Tachometer J 1 Tighten the two screws BAT J2 C10 C19 VC1 D6 RL1 J4 J1 D8 R33 R23 D4 UV3 R21 R22 D7 D1 RL2 RL3 D5 C...

Page 17: ...y does not light 1 Power is OFF 2 Fuse blown 1 Make sure that power is ON 2 Replace fuse After program the open and close limit the motor fails to work 1 The screws on the tachometer on motor are loos...

Reviews: