24
If a continuous change in the load is still recognised during this time, then
the pause cycle is extended another 30 seconds.
The ‘FS20 FMS’ does not return to its normal operating mode until the
constantly changing load is no longer recognised.
If you notice a problem like this, it makes sense to manually increase the
threshold one level.
All timer functions that are active are deactivated during the
pause cycle.
10. Restoring the factory settings
Proceed as follows to restore the factory settings:
• Press the button for approx. 12 seconds (LED goes out after 2 seconds,
on after 5 seconds and off again after 12 seconds)
• Release the button
• The factory settings have now been restored to the ‘FS20 FMS’.