Programming and Using the Code Lock -
Commissioning
1. Example for a Single Operator Programming
1a) operator requirements:
- set the system to single operator (command code / refresh)
- change from the pre-set master code "0000” to your own mas-
ter code "3289”
- enter the operator code 1 "8321”
- enter the operator code 2 "6854”
- set the output relay 1 to "1 sec start??”
- set the output relay 2 to start / stop without short code
- block the keyboard for 15 minutes after 10 false entries
1b) Programming the Example
0000 *
Enter master code (ex factory state) and * key
programming mode
8900 #
Set single operator mode
0 3289 #
3289 is the new master code
1 8321 #
8321 is the new operator code 1
2 6854 #
6854 is the new operator code 2
40 1 #
Relay 1 picks up for 1 sec. when the operator
code 1 has been entered
51 #
Relay 2 with start / stop function with the opera-
tor code 2, without short code
72 10 #
System blocked for 15 minutes after 10 false
entries
*
Programming completed, all the data are stored,
the system is ready for operation.
48
ouvert sur fermé), possible à
l’aide de l’entrée du code
abrégé (les deux premiers
chiffres du code seulement)
52
#
Après avoir entré le code uti-
lisateur et la touche #, le
relais 2 commute (ou bien de
fermé sur ouvert, ou de
ouvert sur fermé), possible à
l’aide de l’entrée du code
abrégé
f) Programmation de la sécurité du système
Code d’accès
Nombre de
Confirmation
Remarques
mauvaises entrées
de code
70
#
Après avoir entré le
faux code 10 fois, l’ap-
pareil bloque l’accès
pour 30 secondes.
71
#
Après avoir entré le
faux code 10 fois, l’ap-
pareil commute la bor-
ne de connexion "DU
OUT" (=Duress) sur
masse. Cette connexi-
on est maintenue jus-
qu’à ce que vous
entriez le code utilisa-
teur 1 et la touche #. A
ces bornes de conne-
xion Duress (sortie
collecteur) vous pou-
vez connecter un
73