User information
5410061-00A01
19
7 Download
data
The last 12 hours VDR data is always retained on the Capsule. There are different
methods (IEC 61996, 4.5.1. Operation) to download data to other memories:
1.
USB memory stick.
Action initiated from the Remote Control Unit and USB
memory stick data can be downloaded to an external laptop, e.g. by the crew or
Investigative Authority Inspector. See Backup procedure
above.
2.
Investigator download.
Action from a temporarily connected laptop e.g. by
Investigative Authority Inspector. Action initiated from the external laptop computer
(see below).
This procedure shall only be used by an Investigative Authority Inspector or a
specially trained Service Engineer. See the Investigative Authority Guide.
3.
PBB or external ship computer or network
. This is an optional connection.
Action initiated from the PBB/external computer. See special instruction in the PBB
chapter above following such installation.
4
.
Capsule download
. Direct connection to a rescued Capsule to an Investigator's
computer. This should be performed only by a person specially trained by Consilium.
If any risk that the Final Recording Medium (FRM) inside the capsule has been
exposed to any damage, contact Consilium Navigation AB, Nacka, Sweden.
7.1 Replay data
Replay of VDR data can be performed on an external PC, equipped with an Ethernet
or USB data input and installed with any of the Consilium Player software’s. See
Professional Player Manual for further instructions.
Summary of Contents for S-VDR S1