User
information
20 5410061-00A01
8 In case of an error
Caution!
Checkpoint 2 - Daily:
Confirm that Remote Control Unit shows
Normal Operation.
Check for Alarms and Warnings and follow instructions.
In case of a deviation/error the VDR notifies the operator on the bridge, with a
message on the Remote Control Unit. The messages are shown in different colours:
Colour Meaning
Info
Red blinking Alarm active
VDR can not fulfill the recording according to
regulations.
Red steady
Alarm
acknowledged
Same status as above but Alarm acknowledged
and cause to the Alarm not yet adjusted
Yellow
Warning
Minor deviation. Inform OW.
Green
Normal operation
Information
8.1 Alarm
During an active alarm the Remote control buzzer is sounding and the red background
is blinking.
•
Turn off the buzzer by pressing the Mute/Ack button once.
This will
silence the buzzer for 5 minutes and if the alarm still is active the buzzer is
turned on again.
•
Acknowledge the alarm by pressing the Mute/Ack button a second time
within 5 min
. When the alarm is acknowledged the buzzer will not go active
again and the red light will be steady. Investigate and if possible adjust the
cause of the alarm (see Error list in chapter 9). The alarm will disappear when
the alarm is acknowledged and the cause of the alarm disappears.
•
The display will be lighten up if it is in night mode if an alarm appears.
1041
COMMUNICATION ERROR
Description: Unit is not
1(2)
responding
Source: Consilium capsule
Unacked alarms 1
ALARM LIST
Mute/Ack button