User
information
26 5410061-00A01
10 System restart
10.1 Regulations
Danger!
The recording process to the final recording medium in the capsule shall not be
interrupted for more than 10 min during the saving process.
Recording may also be terminated under the following circumstances:
a) during essential maintenance purposes whilst the vessel is in port;
b) when the vessel is laid up;
c) upon request by an investigation authority, for example after the vessel had been
involved in a marine incident.
10.2 How to restart
Caution!
Checkpoint 1 - Daily:
If time and date
do not
correspond to UTC, restart the system.
If still not okay contact Consilium.
Caution!
As a precaution it is advisable to
perform a Backup before restarting the system
.
The main unit has two main breakers. One breaker is used for external Power
ON/OFF and the other for Battery ON/OFF. To power off the system both breakers
must be turned off.
It is good practice to switch off battery power before switching off the main power
and turn on main power before turning on the battery power. This will minimize the
load on the batteries.
Battery
ON/OFF
breaker
Power
ON/OFF
breaker
Summary of Contents for S-VDR S1
Page 2: ......
Page 4: ...54100xx 00A01...
Page 5: ...User info Frontpage 1 2 in word doc 1 VDR F1 S VDR S1 User Information User Guide...