User information
5410061-00A01
27
The breakers are separated, one for each line wire. Minus (-) and plus (+) for Battery
breaker and L and N for Power breaker.
Danger!
Be aware of system interrupting regulations (10.1) above before turning off the
system.
Quick guide to switch OFF the system:
1.
Switch off Battery by lifting up the b and – at the same time.
2.
Switch off Power by lifting up the breaker L and N at the same time.
Quick guide to switch ON the system:
3.
Switch on Power by pushing down the breaker L and N at the same time.
4.
Switch on Battery by pushing down the b and - at the same time.
Note!
If only main power is switched off then the VDR will run for another 2 hours on
battery before shutting down. If the VDR is left in this condition for a longer time the
batteries will be drained and they have to be replaced in order to guarantee operation
at the next start.
The system voltage is n28VDC instead of +24VDC. This higher voltage is
needed to have an efficient charging and supervision of the batteries.
Closed breakers = Power ON
Open breakers = Power OFF
Lift up here
Battery
+ -
Power
L N