Attention: Double-sided connection
If the connections of both ends are used, pay special attention to the prevention of accidental incorrect currents at both ends of
the store. Spring-loaded non-return valves or motorised valves must be used.
front & rear
Legend of abbreviations
ST
= Store top
SBT = Store heating buffer top
SBB = Store heating buffer bottom
SB
= Store bottom
C
= Collector
CI
= Circulation
HF
= Heating flow
Syphoning of the connections
Syphon connections should be used.
The height of the Syphon drop should be at least 10 cm,
pipe work should be thin-walled steel or stainless steel tube
- no CU pipe should be used.
Proper syphon connection pipes are offered as accessories.
Double connection to a single outlet
If a storage connection with double connections is planned,
the tee can be attached at the lower end of the siphon, if
the size is not reduced.
internal piping
T D M A - VA R I C A L :
Hydraulic plans