3

 

 

Room temperature below the set temperature. 
Heating is active. 

Variable resistors to 
set temperature 

Set temperature 
achieved 

Temperature control for comfort and setback periods can be used individually or together.  

The temperature control feature will effectively maintain the set room temperature 
within the time period. The target temperature can be set using the knob marked 
COMF located at the back of the controller as shown below. The range is 15ºC - 35ºC. 
Once the room temperature reaches the set temperature, the indicators will change 
from green to orange. When the room temperature drops, heating will became 
active and the indicators will change to green.

 

When the temperature control for setback period is enabled,  the controller will 
activate the heating when the room temperature drops below the set temperature. 
This feature can be used for frost protection or in situations where a minimum room 
temperature must be maintained. The setback temperature can be set using the 
knob marked SETB mounted on the back of the unit as shown above. This can be set 
from 0ºC - 15ºC.

 

Temperature control for Setback period 
To enable temperature control for the setback period, the switch 2 is set to ‘ON’ position as shown below.  

If the heating is active in the setback mode, the indicators will illuminate red and green. 

Temperature control for the comfort period 
To enable temperature control, the switch 1 is set to ‘ON’ position as shown below. The temperature control is only 
active after motion detection and will end after the set time period ends. After the set time period ends, the tem-
perature is allowed to fall. If the room temperature is higher than the set comfort temperature, the heating will not 
be activated after the motion detection. 

4. Presence detection with Time and Temperature Control 

The temperature and/or timer settings can be changed after installation. It is important to switch the power off to 
the controller before the changes are made. After the changes are made and the power is restored the new 
settings will take effect. 

5. Changing temperature or timer settings after installation 

The controller can be deactivated by using any external device with voltage free contacts. 
For example, timers or a building management system.  

If this function isn’t used, a wire link across the external input connectors must be used.  
When the external input connection is open, the indicators will light up red and the 
presence detection and heating will be disabled. However, setback mode will still operate 
at low temperature. 

6. External Input 

The PIR detection range is up to 5 metres. The detection area is 60 degrees vertical and 120 degrees horizontal.  
This can be tested in the test mode after the pairing. Check the Pairing section for more details explaining the test 
mode.  

7. PIR Detection Range 

Summary of Contents for SLPIR

Page 1: ...ghts The correct electricity supply voltage is shown on the rating label attached to the appliance Reasonable care has been taken to ensure that this guide is accurate at the time of printing In the interest of progress the Company reserve the right to vary specifications from time to time without notice SLPIR CONTROLLER 13984111 Iss 01 CUSTOMER HELPLINE Should you need any advice on the use of yo...

Page 2: ...nts around the sensor show remaining time Each segment equals 1 4 of the total time Switch 3 4 OFF 5 minutes Switch 3 ON 15 minutes Switch 4 ON 30 minutes Switch 3 4 ON 60 minutes 3 Presence detection with Timer To set ON time period after the motion was detected the switches are set as shown below 60 MINS 45 MINS 30 MINS 15 MINS Controller functionality After the motion detection the controller a...

Page 3: ...red and green Temperature control for the comfort period To enable temperature control the switch 1 is set to ON position as shown below The temperature control is only active after motion detection and will end after the set time period ends After the set time period ends the tem perature is allowed to fall If the room temperature is higher than the set comfort temperature the heating will not be...

Page 4: ...Power ON the controller or controller and heater together Wait 2 seconds Power OFF the controller or controller and heater together Wait 2 seconds Power ON the heater Power ON the controller If the sequence was followed correctly the 4 light segments will flash yellow to indicate pairing After the pairing is finished the light segments will change to green If the pairing was successful the applian...

Reviews: