6. Function
AIO-121602LN-USB, AIO-120802LN-USB
69
Conversion data
The following equation represents the relationship between input data and voltage.
Voltage = Input data x (Max. range value - Min. range value) / Reso Min. range value
The value of resolution for the 12-bit device is 4096.
< ± 10V range >
The following table shows the relation between AD conversion data and voltage.
Voltage
Conversion data (12-bit)
+9.995V
4095
:
:
+0.005V
2049
0V
2048
-0.005V
2047
:
:
-10.000V
0
Ex.: When input data 3072 is input at a resolution of 12-bit in the ±10V range
Voltage = 3072 x (10 - (-10)) ÷4096 + (-10)
= 5.0
< 0 - 10V range >
The following table shows the relation between AD conversion data and voltage.
Voltage
Conversion data (12-bit)
+9.998V
4095
:
:
+5.002V
2049
+5.000V
2048
+4.998V
2047
:
:
0V
0
Ex.: When AD conversion data 3072 is input at a resolution of 12bit in the 0 - 10V range
Voltage = 3072 x (10 - 0) ÷ 4096 + 0
= 7.5