2. System Reference
IPC-BX955 User’s manual
9
Table 2.2. Installation Environment Requirements
Model
IPC-BX955D-DCxxx
Ambient
specifications
Operating temperature
*6
(1) Horizontal installation : 0 - 50
C
(2) Vertical installation other than above : 0 - 45
C
Storage temperature
-10 - 60
C
Humidity
10 - 90%RH (No condensation)
Floating dust particles Not to be excessive
Corrosive gases
None
Line-noise
resistance
Line noise
AC line /
2kV *7,
Signal line /
1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Static
electricity
resistance
Contact discharge /
4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Atmospheric discharge /
8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
Vibration
resistance
Sweep
resistance
110 - 57Hz/semi-amplitude 0.375 mm 57 - 500Hz/5.0G
60 min. each in x, y, and z directions
(JIS C 60028-2-6-compliant, IEC 60068-2-6-compliant)
Impact resistance
100G, half-sine shock for 6 ms in x, y, and z directions
(JIS C 60068-2-27-compliant, IEC 60068-2-27-compliant)
Grounding
Class D grounding (previous class 3 grounding), SG-FG / continuity
*6 : For more details on this, please refer to chapter 3, “Installation Requirements”.
*7 : When AC adapter “IPC-ACAP12-04” is used.
Power Management Features
-
Support both ACPI (Advanced Configuration and Power Interface) and legacy (APM) power
management.
-
ACPI v2.0 compliant
-
APM v1.2 compliant
-
Support hardware automatic wake-up