Allows you to edit the internal sequence launched by the RUN command from the MODE menu.
Number of scenes included in the sequence. 48 scenes max. If the
value is S-07, the sequence will include 7 scenes.
Allows you to automatically save the number of scenes. The numbers
following RE indicate the position of the current step.
First scene of the sequence
Edit each channel of the current scene. Each submenu
allows you to edit a channel.
For instance: To edit channel 5 you will select C-05, and
confirm with ENTER. The display will then indicate 05-
XX, XX being the hexadecimal DMX value.
Change this value with the UP and DOWN buttons.
Confirm your choice with ENTER and move onto the
next channel.
You must confirm your choice for each channel before
moving onto next settings.
Configures the current scene duration from 0,2 to
199,8 ms (001 to 999 x 0.2 ms)
Allows you to retrieve scenes from an external
controller.
(see below for more details)
Last scene of the sequence
Note: The number of the last scene is the value selected in the STEP submenu.
Retrieving scenes from an external controller
1 - Connect the controller to the Evora-SP60.
2 - Select the desired scene.
3 -Position the STEP submenu on SC-01, confirm with ENTER. The display will indicate C-O1.
4 -Select CNIN and confirm with ENTER, the display will indicate SC-O2 if the scene has been saved
properly.
5 - Set the scene duration with the TIME submenu.
6 - Move onto the next scene.
7 - Repeat steps 3 to 5 for each scene. The number of scenes is determined by the value chose in
the STEP submenu.
Note
: The controller only acts on the memory of the projector, not on its movements.
Switch to RUN mode to visualise saved scenes (see page 7).