45
TECHNICAL SPECIFICATIONS
TRADEMARK
Continental
Edison
MODEL IDENTIFICATION
CEHDG60IV
(BX2-2-J1E6H01)
ANNUAL ENERGY CONSUMPTION (AEC
hood
) (kWh/year)
65
TIME INCREASE FACTOR (f)
1,2
ENERGY EFFICIENCY INDEX
67,8
ENERGY EFFICIENCY CLASS
B
FLUID DYNAMIC EFFICIENCY
21,4
FLUID DYNAMIC EFFICIENCY CLASS
C
LIGHTING EFFICIENCY (LE
hood
) (lux/W)
36,1
LIGHTING EFFICIENCY CLASS
A
GREASE FILTERING EFFICIENCY (GFE
hood
)
81,9
GREASE FILTERING EFFICIENCY CLASS (GFE
hood
)
C
MEASURED AIR FLOW RATE AT BEST EFFICIENCY POINT
(Q
BEP
) (m
3
/h)
321,1
MEASURED AIR PRESSURE AT BEST EFFICIENCY POINT
(P
BEP
) (Pa)
345
MAXIMUM AIR FLOW AT HIGHEST SETTING (Q
MAX
) (m
3
/h)
639,2
MINIMUM AIR FLOW AT WORKING POINT (IN NORMAL
USE) (m
3
/h)
366
MAXIMUM AIR FLOW AT WORKING POINT (IN NORMAL
USE) (m
3
/h)
610
MAXIMUM AIRFLOW AT BOOST SETTING IF APPLICABLE
(Q
MAX
) (m
3
/h)
-
MEASURED
ELECTRIC
POWER
INPUT
AT
BEST
EFFICIENCY POINT (W
BEP
) (W)
143,9
NOMINAL POWER OF THE LIGHTING SYSTEM (W
L
) (W)
1,5 x 2
AVERAGE ILLUMINATION OF THE LIGHTING SYSTEM ON
THE COOKING SURFACE (E
middle
) (lux)
108
WEIGHTED SOUND POWER LEVEL AT MINIMUM SETTING
(L
WA
) (dB)
71
WEIGHTED SOUND POWER LEVEL AT MAXIMUM SETTING
(L
WA
) (dB)
75
SOUND POWER LEVEL OF BOOST IF ANY (L
WA
) (dB)
-
MEASURED POWER CONSUMPTION OFF MODE (P
O
) (W)
0
MEASURED POWER CONSUMPTION IN STANDBY MODE
(P
S
) (W)
-
The above values are tested and calculated according to regulation EU65-2014,
UE66-2014.