37
W415-0680 / 04.10.08
FIGURE 119
FIGURE 120
OPTIONAL FAN INSTALLATION
FIGURE 121
FIGURE 122
A
A
B
B
FIGURE 118a
FIGURE 118a
C
C
FIGURE 118b
FIGURE 118b
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be connected and
grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C
ANADIAN
ELECTRICAL
CODE
in Canada or the ANSI/NFPA 70
NATIONAL
ELECTRICAL
CODE
in the United States.
To safely install the fan, turn off the electricity fi rst.
If the fi replace was not previously equipped with a fan:
Route a grounded 2-wire, 60hz
power cable to the junction box. At this point, it must be strain relieved and insulated.
The wire harness provided in this kit is a universal harness. When installed, ensure that any
excess wire is contained, preventing it from making contact with moving or hot objects.
To ease installation of the fan, remove the hinge screen and valve control door (lower louvres)
from the base of the fi replace.
Position the vibration reducing pad into the clip and onto the threaded stud at the other end, pierc-
ing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad. Slide the fan
assembly past the controls and into the clip. Secure using the lock washer and nut provided.
Plug the harness cord into the receptacle.
FIGURE 123
FIGURE 124
GD36 THERMOSTATIC SENSOR CONTROL
This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown
above, which may be ordered from your Wolf Steel / Authorized dealer.
With the thermostatic sensor option, the fan, when turned on, becomes thermally activated,
and will automatically run approximately 15-30 minutes after the fi replace has been lit and
for approximately 30-45 minutes after the fi replace has been turned off.
Use of the fan increases the output of
heat.
Unplug the power cord from the receptacle.
Connect all wires as shown.
Attach and secure the sensor assembly bracket to the securing
stud located next to the receptacle/junction box at the bottom left of the unit
using the lock washer and wing nut. Ensure that the thermodisc touches the
fi rebox wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects.
Tilt the blower onto its side. Slide it past the controls and into the clip
(C)
. Secure to the threaded stud using the lock washer and wing nut
provided. Ensure that the blower does not touch the fi replace base
or the fi rebox.
Attach the connectors from the black and white wires to the thermo-
disc and secure the thermodisc bracket to the securing stud at the
bottom left of the unit using a lock washer and wing nut. Ensure that
the thermodisc touches the fi rebox wall.
Attach the connectors from the black and red wires to the blower.
Attach and secure the variable speed switch using the nut provided.
Plug the harness cord into the receptacle.
NOTE:
To improve access to the variable speed control, we recommend bending
the mounting bracket forward by approximately 10°.
The wire harness provided in
this kit is a universal harness. When installed, ensure that any excess wire is
contained, preventing it from making contact with moving or hot objects.
Drywall dust will penetrate into the blower bearings, causing irreparable
damage. Care must be taken to prevent drywall dust from coming into con-
tact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.
Summary of Contents for BCDV2CFN
Page 1: ...1 W415 0680 04 10 08 10 00 W415 0680 04 10 08...
Page 7: ...7 W415 0680 04 10 08 FIGURE 8...
Page 46: ...46 W415 0680 04 10 08...
Page 51: ...51 W415 0680 04 10 08 NOTES...
Page 52: ...52 W415 0680 04 10 08 NOTES...