DLREF305
REFRIGERATORS
CHARACTERISTICS
Reach-In
Pass-Thru
Reach-In
Pass-Thru
Reach-In
Pass-Thru
DIMENSIONAL DATA
Net Capacity (cu. ft.)
21
21
50
50
72
72
Width, Overall (in.)
26
26
52
52
78
78
Depth, Overall (Incl. Hdls.) (in.)
35
1
/
2
39
35
1
/
2
39
35
1
/
2
39
Depth (Less Door(s)) (in.)
32
32
32
32
32
32
Depth (Doors(s) Open 90°) (in.)
55
1
/
2
79
55
1
/
2
79
55
1
/
2
79
Clear Door Width (in.)
19
3
/
8
19
3
/
8
19
3
/
8
19
3
/
8
19
3
/
8
19
3
/
8
Clear Full-Door Height (in.)
58
5
/
8
58
5
/
8
58
5
/
8
58
5
/
8
58
5
/
8
58
5
/
8
Clear Half-Door Height (in.)
27
1
/
2
27
1
/
2
27
1
/
2
27
1
/
2
27
1
/
2
27
1
/
2
Height, Overall (Inc. 6" Legs)(in.)
83
1
/
4
83
1
/
4
83
1
/
4
83
1
/
4
83
1
/
4
83
1
/
4
No. of Full Door(s)
1
2
2
4
3
6
No. of Half Door(s)
2
4
4
8
6
12
No. of Shelves
3
3
6
6
9
9
Shelf Area (sq. ft.)
20.4
20.4
40.8
40.8
61.2
61.2
Tray Slide Capacity (Half)
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
12 ea.
Tray Slide Capacity (Full)
25 ea.
25 ea.
25 ea.
25 ea
25 ea
25 ea
REFRIGERATION DATA
Condensing Unit Size (H.P.)
1
/
4
1
/
4
1
/
3
1
/
3
1
/
2
1
/
2
Capacity (BTU/hr)**
1940
1940
2560
2560
4010
4010
ELECTRICAL DATA
Cabinet Specifications
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
Feed Wires (Incl. Ground)
3
3
3
3
3
3
Condensing Unit Specs.
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
Total Amperes
6.9
7.2
9.1
9.8
12.4
13.4
Cabinet Amperes
1.6
1.9
1.9
2.3
2.9
3.9
Defrost Amperes
-
-
-
-
-
-
Power Supply Cord
yes
yes
yes
yes
yes
yes
SHIPPING DATA
Height – crated (in.)
85
1
/
2
85
1
/
2
85
1
/
2
85
1
/
2
85
1
/
2
85
1
/
2
Width – crated (in.)
31
5
/
8
31
5
/
8
64
64
90
90
Depth – crated (in.)
42
42
42
42
42
42
Volume – crated (cu.ft.)
65
65
133
133
187
187
Weight Std – crated (lbs.)
320
350
535
595
740
825
Weight SS – crated (lbs.)
380
410
615
675
855
945
Weight Std – uncrated (lbs.)
220
250
365
425
530
620
Weight SS – uncrated (lbs.)
280
310
445
505
645
735
DL1R-SS DL2R-SS
DL3R-SS
One Section Two Section Three Section
**Rating @ +25°F Evaporator, 90° Ambient
Note: All Specifications subject to change without notice.
Note: If the cabinet is located directly against a wall and/or under low ceiling, a minimum clearance of 2" is
required.
Cabinet upper side panels and refrigeration plug system can be easily removed and reinstalled at installation site
where space limitations are confining.
A Division of National Refrigeration & A/C Products, Inc.
539 Dunksferry Road Bensalem, PA 19020
(800) 523-7138 Fax: (215) 244-9579
www.continentalrefrigerator.com
32"
34"
35
1
/
2
"
52"
83
1
/
4
"
83
1
/
4
"
6" Adjustable Legs
6" Adjustable Legs
78"
Digital Thermometer
Digital Thermometer
Digital Thermometer
83
1
/
4
"
26"
6" Adjustable Legs