Initial Set Up and PLC Reset
Initial Set Up
Check to be certain that the motor rotates in the direction of the arrow
shown on the motor housing. If motor rotation is opposite of the direction of
the arrow, for a 3 phase circuit, reverse any two hot wires in the electrical
plug.
Damage to the pump can result if the motor does not rotate in the correct
direction.
Check the oil level in the sight glass on the front of the tank. 8 U.S. gallons of
ISO 46 hydraulic oil are required to completely refill the tank.
Oil can be drained from either of the two ports at the bottom of the tank. An
additional oil cooler, while not normally required, can be plumbed into the
two ports at the rear of the tank.
Lubrication
Lubricate the crimping head after each 400 crimping cycles or at the start of
each shift if the crimper is used in a production setting.
Bring the master dies to the fully closed position, and lubricate the master
dies through the 10 holes in the protective plates as illustrated. With the dies
still in the fully closed position lubricate the fittings visible through the 2
bottom lubrication holes in the protective plate of the crimper.
Note that
there are also 8 lubrication fittings on the side of the machine as shown on
the Component Identification page.
Use only a high quality grease. Failure to do so may result in damage to the
wearing surfaces.
PLC Reset Procedure
The PLC (Programmable Logic Controller) requires a
relatively constant source of electrical power. Power
surges, outages or drops in power can cause the PLC to
lose its settings. This may result in missing or misplaced
information on the controller screen.
Resetting the PLC to its original settings is a
simple procedure
•
Turn the main power switch to OFF.
•
Open the front of the Control Panel.
•
Power up the crimper from the main power switch. The crimper must
be powered on during the PLC reset procedure.
•
Move the three position toggle switch on top of the PLC right to the
STOP position and then left to the RUN position.
•
Return the toggle switch to the center TERM position.
•
Repeat for the other PLC Unit.
•
Turn the main power switch to OFF and replace the front panel. The
PLC and the crimper should now operate normally.