background image

© 2013, Continuum Footspas, LLC        

April, 2013

Phone:

262 754 4900

Fax:

262 754 4901

Toll free:

877 255 3030

ContinuumFootspas.com

MAESTRO

®

PEDICURE SPA

NOTES:

Summary of Contents for MAESTRO

Page 1: ...MAESTRO PEDICURE SPA OWNER S MANUAL Continuum Footspas LLC P O Box 363 Brookfield WI 53008 Toll Free 1 877 255 3030 Telephone 262 754 4900 Fax 262 754 4901 continuumfootspas com ...

Page 2: ...intenance negligence improper cleaning or any other circumstances beyond Continuum Footspas control In order for your Limited Warranty to be valid your Maestro Pedicure Spa must be installed by a licensed professional in accor dance with Continuum Footspas installation instructions EXCLUDED FROM LIMITED WARRANTY 1 Unauthorized repairs 2 Damage due to freight accident natural disaster and or abuse ...

Page 3: ...s Maximum weight capacity of your pedicure chair is 300 pounds Never bring or operate any electrical device in or near your pedicure chair Always enter and exit your pedicure chair very slowly and carefully Never stand in the basin Avoid excessive water temperatures This can be dangerous and water temperature must be checked before each use Maximum operational water temperature should never exceed...

Page 4: ... TO INSTALLATION ONE SHOULD CONTACT THEIR LOCAL BUILDING INSPECTOR TO MAKE SURE ALL LOCAL CODES ARE COMPLIED WITH WARNING Possible Health Risks Clients whose feet or legs are inflamed for any reason or clients who have open wounds should never be allowed to use a pedicure chair If there is any sign of fungal infection fracture swelling or persist ent pain clients should consult their physician bef...

Page 5: ...ULD BE USED WITH ANY CONTINUUM PEDICURE CHAIR WARNING TO REDUCE THE RISK OF BURNS ELECTRIC SHOCK FIRE OR INJURY TO PERSONS Any servicing of your pedicure chair must be performed by authorized service personnel only DO NOT operate your pedicure chair if it has a damaged cord or plug Keep cord away from heated surfaces DO NOT use outdoors Hot Cold Water Supply and Drain All plumbing connections must...

Page 6: ...ected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pedicure chair without the test button being...

Page 7: ...and void if pedicure chair is not properly secured to floor Installation Instructions Step 1 Utilizing a level carefully adjust the four 4 leveling feet It is extremely important that your pedicure chair is level Note All leveling feet have been factory adjusted prior to shipment In most cases no further adjustment should be necessary The entire pedicure chair may be raised or lowered slightly to ...

Page 8: ...irements and procedures Cleaning and Disinfecting Products Your state board requires disinfecting of your pedicure tub Continuum STRONGLY recommends Splish Splash One Step Disinfectant The following page outlines product benefits for all pedicure chairs together with contact information While other EPA registered products are available for maintaining pedicure tubs we have found Splish Splash to b...

Page 9: ...ng manicure stations and countertops mix one 1 Fluid Ounce of Splish Splash One Step Disinfectant in one 1 gallon of water For spray bottle mix 1 4 Fluid Ounce of One Step Disinfectant in 32 Ounces of water Sponge or spray on wait ten 10 minutes and wipe dry PLASTIC INSTRUMENTS For plastic instruments mix one 1 Fluid Ounce of Splish Splash One Step Disinfectant with one 1 gallon of water and fill ...

Page 10: ...the soapy solution and rinse the basin 5 Refill the basin with clean water and circulate the correct amount read the label for mixing instructions of the EPA Registered Liquid Disinfectant Splish Splash is strongly recommended through the basin for 10 minutes 6 Drain rinse and wipe dry with a clean paper towel 7 Allow the basin to dry completely At least once each week overnight procedures After c...

Page 11: ...7 8 9 10 Client Time Staff Date m d yr _______________________________ Station __________ Serial ______________ Service No 1 2 3 4 5 6 7 8 9 10 Client Time Staff Date m d yr _______________________________ Service No 1 2 3 4 5 6 7 8 9 10 Client Time Staff Date m d yr _______________________________ ...

Page 12: ...t Use of this product should be pleasant and comfortable Should pain or discomfort result discontinue use and consult your physician WARNING WHEN USING CONTINUUM PEDICURE CHAIRS BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING 1 READ AND FOLLOW ALL INSTRUCTIONS 2 DANGER To reduce the risk of injury do not permit children to use pedicure chairs unless they are closely supervised ...

Page 13: ...as LLC April 2013 MAESTRO PEDICURE SPA Features of the Maestro Pedicure Spa 1 Adjustable headrest 2 Client chair control keypad 3 Beverage holder 4 Pivoting leg supports 5 Basin overflow gravity drain only 1 2 3 4 5 Figure 1 ...

Page 14: ...ovable foot massage rollers 6 7 8 13 14 15 6 Chair Release Lever 7 Filler Sprayer 8 Drain Handle 9 I Fill Button start stop water and jets 10 Hot Cold and Flow Control Handle 11 Technicians Chair Control Keypad 12 Drain Pump ON OFF only if optional drain pump is ordered 9 10 11 12 Figure 2 Figure 3 ...

Page 15: ...lowing the chair to swivel This must be done each and every time a client enters or exits the chair Please note In order for the chair locking mechanism to work proper ly one must sit normally in the chair that is to say NOT on the outer edge of the chair but rather sit ting back in the chair This allows for the locking pin to engage and disengage easily When entering Lift the lever allowing the c...

Page 16: ... cold water from mixing inside an open water valve once water stops flow ing close valve handle 6 by gently pushing it to the down position Furthermore Neoperl check valves have been installed on the brass hot and cold water inlets located in the back of the spa This will prevent any cross connection of hot and cold water Adjusting Sensor Delay Time Setting As a result of water pressure and or bas...

Page 17: ...TO DRAIN With optional factory installed drain pump Step 1 Slowly turn Chrome Drain Handle 8 located on the the front of your pedicure chair This raises the pop up 14 located on the bottom of the basin allowing water to drain Step 2 Press chrome button marked Drain 12 located on the right side of the basin shroud This will activate the drain pump When basin is fully emptied depress button once aga...

Page 18: ...y minute Massage timers are activated by pressing PWR LOW HEAT Activates Heat and turns low heat on HIGH HEAT Activates Heat and turns high heat on SELECT ZONES Let you choose any or all zones for massage Press any zone 1 3 to massage specific area ZONE 1 Upper back massage ZONE 2 Lower back massage ZONE 3 Thigh region massage WAVE Massage moves up and down in a wave like action PULSE Massage turn...

Page 19: ...cedures as outlines by your state board one may chose to scrub the basin as well Simply use a fine nylon scouring pad ie Scotch Bright 6448 or 7448 together with a good clean ing powder ie Bar Keeper s Friend This additional cleaning will keep the basin of your Maestro Pedicure Spa looking brand new for many years NOTE DO NOT USE THE NYLON SCOURING PAD ON THE ADJACENT LEG SUPPORTS Upholstery Simpl...

Page 20: ...e up position It may be necessary to gently push down on the leg support to make sure it locks securely To unlock lift up and carefully position to side of basin Optional manicure trays are available depending on date of manufacture for The Maestro When manicure trays are ordered with the pedicure chair brackets will be factory installed Simply attach the trays with provided wood screws making sur...

Page 21: ... 2013 Continuum Footspas LLC April 2013 Phone 262 754 4900 Fax 262 754 4901 Toll free 877 255 3030 ContinuumFootspas com MAESTRO PEDICURE SPA NOTES ...