INPUTS
OUTPUT
Eight digital inputs coming from SPST contacts can be wired to terminals 7-14.
Common return for contacts at terminal 6.
Using electronic switches, terminal 6 is the positive leg.
In order to avoid false triggering, contacts will be considered closed or open after
3 seconds from stable condition.
Modifying the configuration by means of GsmSuite, either in local or remote mode
it will be possible to change:
Debounce time from 1 to 99 seconds.
Enable and disable input closing detection.
Enable and disable input opening detection.
Contact voltage < 20 V
Contact current < 2 mA
9 x 2.5 mm (AWG14) screw connector
Process or appliance can be controlled by means of 1 SPST relay contact
available between terminals 3-4.
Rated current 4 A
Rated voltage 250 Vac
Max breaking capacity 2500 VA
Minimum contact load 100 mA, 12 V
Cadmium free contacts
Insulation 250 V (IEC60664 / VDE0110b - cat. III / C)
Surge voltage coil contacts: 4000V
Dielectric strength coil-contacts 2500V
open contact circuit 1000V
4 x 2.5 mm (AWG14) screw connector
¡
¡
¡
DC
RMS
RMS
RMS
2
2
DECLARATION OF CONFORMITY
R&TTE Directive 1999/5/EC
Manufacturer: Contrive, Srl
Via Enrico Fermi 18 24040 Suisio Italy
Brand:
Contrive
Equipment name:G / Gp
Equipment type: GSM/GPRS modem
EMCC DR. RAŠEK, GmbH
Moggast, Boelwiese 5
91320 Elbermannstadt Germany
Company identification:
Product identification:
We declare on our sole responsibility, that the product described above
is in compliance with the essential requirements of the 1999/5/CE Directive:
EN 301 489-1
EN 301 489-7
EN 61326
EN 55024
EN 300 607
and all tests were carried out
Notified Body:
Health and safety requirements pursuant to clause 3.1a:
Protection requirements concerning EMC clause 3.1b:
Measures for the efficient use of the radio frequency spectrum clause 3.2:
EN 301 511
EN 60950-1
GSM900/1800 essential requirements for mobile stations
Safety of information technnology equipment
Electromagnetic compatibility
ElectroMagnetic compatibility and Radio spectrum Matters
Specific conditions for mobile and portable radio and ancillary equipments
ElectroMagnetic compatibility measurement, control and laboratory use
Information technology equipment - Immunity characteristics
Radio spectrum matters
NOTE:
Class B equipment (domestic) emission level applied.
Class A equipment (industrial) immunity level applied.
Suisio, Italy February 21, 2006
¡
¡
¡
CONTRIVE RESERVES THE RIGHT TO MODIFY THE CHARACTERISTICS STATED
IN THIS INSTRUCTION MANUAL AT ANY TIME AND WITHOUT PRIOR NOTICE.
© COPYRIGHT 2002...2005 CONTRIVE SRL ITALY. ALL RIGHTS RESERVED.
GA
GX
The embedded antenna is located under the front panel. This omnidirectional
antenna can work properly if the front side of the device is not shielded by metallic
frames (i.e.: the GsmA is installed inside a metal cabinet).
An external dual-band antenna must be connected to the RF interface, implemented
as a 50 FME male coaxial jack at the end of a short RG174 cable stub exiting from
the top side of the device. The antenna must fulfil the requirements given below:
We recommend a VSWR max of 1.5:1 although a VSWR max of 2:1 can be accepted
without affecting performance and certification.
The DC impedance is floating but there is no problem when using antennas that
present a short to ground.
W
CONTRIVE S.R.L.
Via Enrico Fermi 18 I-24040 SUISIO (Bergamo)
Tel. +39 (0)35 4948236 Fax +39 (0)35 4933759
B1018.EN / 0211
www.gsm-control.biz
Dual band EGSM900 and GSM1800 for data, sms, fax and voice applications
Full Type Approved and compliant with ETSI GSM Phase 2+
Output power:
Class 4 ( 2W @ 900 MHz )
Class 1 ( 1W @ 1800 MHz )
Temperature:
operating -20 to 55°C
storage and transport –30 to 85°C
Relative humidity:
operating 5 to 95% non-condensing
storage & transport 5 to 95% condensation allowed outside
Enclosure:
EN-50022 rail 4 modules, polycarbonate, UL94 -V0
Overall dimensions: mm 71 x 90 x 58 ( W x H x D )
Weight:
200 g
Degree of protection: IP 40 (
IEC 529) properly fitted
EN-60529 /
Power supply:
12 V DC ±20% polarity independent
12 V AC ±20%
< 30 mA @ 12 V DC in standby mode
< 100 mA @ 12 V DC in standby mode, relays ON
< 200 mA @ 12 V DC in communication mode
<
1 A @ 12 V DC max peak current
2 x 2.5 mm (AWG14) screw connector
This unit can be supplied either by alternating or direct current, polarity
independent. Power supply connection on terminal 1 and 2, top right side.
The power supply unit must meet the demands placed on SELV [1] circuits in
accordance with EN60950.
The power supply must not be shared with other equipment: suggested power
supply source is a simple 12VAC / 5VA transformer.
The maximum permissible connection length between device and supply source
is 3 m. Overvoltages are suppressed by internal varistor.
[1] Safety Extremely Low Voltage
2
This device should be installed only by qualified personnel. Carefully read the
instruction manual in its entirety and keep it safe for future reference.
It is essential to know the information and comply with the instructions given in the
manual to ensure the fitting is installed, used and serviced correctly and safely.
This RF unit is not designed for and intended to be used in portable applications
(within 20 cm or 8 inches of the body of the user) and such uses are strictly prohibited.
This unit is not authorised for use as critical component in life-support devices or
systems unless a specific written agreement has been given.
If incorrectly installed in a vehicle, the operation of GSM device could interfere with
the correct functioning of vehicle electronics. Verification of the protection of vehicle
electronics should form a part of the installation.
Regulations must be considered to operate a vehicle’s light or horn on public roads.
No complex software or hardware system is perfect.
Bugs are always present in a system of any size.
In order to prevent danger to life or property, it is the responsibility of the system
designer to incorporate redundant protective mechanism appropriate to the risk
involved.
All units are 100% functionally tested. Specifications are based on characterisation
of tested sample units rather than testing over temperature and voltage each unit.
Contrive disclaims all liability for damage to the fitting or to other property or persons
deriving from installation, use and maintenance that have not been carried out in
conformity with this instruction manual, which must always accompany the fitting.
The G is an industrial DIN rail GSM modem for the supervision and control
of remote inputs and outputs by means of enhanced features available through GSM
network.
Industrial standard interface and an integrated SIM card reader mean it can be used
rapidly, easily and universally to quickly implement new applications in telemetry,
telematics and remote control. All interfaces are integrated in the housing.
The connections are suitable for use in domestic and industrial environments.
DIMENSIONS [mm]
SAFETY INFORMATION
PRODUCT FEATURES
ANTENNA
PRODUCT DESCRIPTION
58
90
71
r
If the device has been stored in a cold environment, then condensation can
occur. Before starting operations, the device must be absolutely dry.
Thus, an acclimatization period of at least three hours must be observed.
In order to avoid possible damage, we recommend that you only use the
specified accessories.
These have been tested and shown to work well with this unit.
i
Do not install this unit near medical devices like pacemakers or hearing
aids. This unit may interfere with the operation of these devices.
Switch off this unit when flying.
Secure it so that it cannot be switched on inadvertently.
Do not install this unit near petrol stations, fuel depots, chemical plants or
blasting operations when this unit can disturb the operation of technical
equipment.
Interference can occur if this unit is used near televisions, radios or
personal computers.
BUILT ON PROVEN TECHNOLOGY
POWER SUPPLY
INPUTS / OUTPUT
Frequency TX
Frequency RX
Impedance
VSWR
TX max
RX max
Polarization
Typical gain
880 to 915 MHz
925 to 960 MHz
50 ohms
1.5 : 1
1.5 : 1
Linear
0 dBi in one direction at least
1710 to 1785 MHz
1805 to 1880 MHz
1 2 3 4 5 6 7 8
INSTALLATION
This unit can be installed on any standard EN-50022 rail by simple snap-in.
A minimum protection degree IP40 must be guaranteed, raised to IP54 for open-
air application.
A. Power Supply input
2 x 2,5mm (AWG14)
B. Input and output terminals
12 x 2,5mm (AWG14)
C. Input red led status indicators
D. Output green led status indicator
X. External antenna (type X only)
RG174 + FME male jack
S. GSM operation LED indicator
OFF
No power supply
ON
Module switched ON
Not registered on the network,
missing SIM or invalid PIN
SLOW FLASH
Module switched ON
Registered on the network
QUICK FLASH
Module switched ON
Registered on the network
Communication in progress
2
2
¡
¡
¡
¡
PERMANENTLY
200ms ON / 2s OFF
200ms ON / 600ms OFF
à
õ
õ
X
A
B
1
13
12
11
10
9
8
7
6
5
4
3
2
14
S D
C
Your GsmAlarm is the product of advanced engineering, design and craftmanship
and should be treated with care. The suggestion below will help you to enjoy this
product for many years.
Both fixed and mobile applications are allowed, as defined below:
means that the device is physically secured at one location and is not able
to be easily moved to another location.
means that the device is designed to be used in other than fixed locations
and generally in such a way that a separation distance of at least 20 cm (8 inches)
is normally maintained between the transmitter’s antenna and the body of the user
or nearby persons.
Do contact an authorized service center in the unlikely event of a fault in the unit.
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
Do not expose the unit to any extreme environment where the temperature or
humidity are out of operating range.
Do not use or store the unit in dusty or dirty areas. Its moving parts (SIM holder for
example) can be damaged.
Do not use chemical cleaning agent on the unit or the SIM card.
Do not attempt to disassemble the unit or remove any part or label.
There are no user serviceable parts inside.
Do not expose the unit to water, rain or spilt beverages. It is not waterproof.
Do not abuse the unit by dropping, knocking or violenty shaking it.
Rough handling can damage it.
Do not place the unit alongside computer discs, credit or travel cards or other
magnetic media. The information contained on these devices may be affected.
This unit is under your responsibility. Please treat it with care respecting all local
regulations. It is not a toy. Therefore, keep it in a safe place at all times and out of
the reach of children.
Treat the SIM card with the same care as your credit card: do not bend or scratch
or expose it to static electricity.
Try to remember your unlock and PIN codes. Become familiar with and use the
security features to block unautorised use and theft.
Fixed
Mobile
CARE AND MAINTENANCE
0678
1018.01.00 GA
1018.02.00 GA
1018.01.01 GX
1018.02.01 GX
1018.01.10 GpA
1018.02.10 GpA
1018.01.11 GpX
1018.02.11 GpX
EMBEDDED ANTENNA
EMBEDDED A BACKUP BATTERY
EXTERNAL ANTENNA
EXTERNAL A BACKUP BATTERY
EMBEDDED ANTENNA
EMBEDDED A BACKUP BATTERY
EXTERNAL ANTENNA
EXTERNAL A BACKUP BATTERY
B
B
B
B
G
GSM REMOTE MONITOR
GSM/GPRS REMOTE MONITOR
Gp
USER GUIDE
1 2 3 4 5 6 7 8
THE INFORMATION CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE
WITHOUT NOTICE. PRODUCT NAMES, CORPORATE NAMES OR TITLES USED WITHIN
THIS DOCUMENT MAY BE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER
COMPANIES AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE
READERS’BENEFIT,AND WITHOUT INTENTION TO INFRINGE.
WHILE EVERY EFFORT HAS BEEN MADE TO MAKE SURE THE INFORMATION IN THIS
DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES
WHATSOEVER FOR LOSS RELATING TO THIS DOCUMENT.
WARRANTIES
CONTRIVE GUARANTEES FOR TWO YEARS FROM THE DATE OF MANUFACTURE OF
ITS PRODUCT TO REPLACE, OR, AT ITS OPTION, TO REPAIR ANY PRODUCT OR PART
THEREOF WHICH IS FOUND DEFECTIVE IN MATERIAL OR WORKMANSHIP OR WHICH
OTHERWISE FAILS TO CONFORM TO THE DESCRIPTION OF ITS SALES ORDER.
CONTRIVE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER
WARRANTY EXPRESS OR IMPLIED. IN NO EVENT SHALL CONTRIVE BE LIABLE FOR
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE WHICH MAY ARISE IN
CONNECTION WITH SUCH PRODUCTS.
THE WARRANTY DOES NOT APPLY IN CASE OF IMPROPER USE