Warnings and considerations

WARNING! 

Turn OFF electrical power before installing or servicing this 

product. Improper use or installation can cause SERIOUS INJURY, DEATH 

or LOSS/DAMAGE OF PROPERTY.

ATTENTION!

 Coupez l’alimentation électrique avant d’installer ou de 

réparer ce produit. Une mauvaise installation ou utilisation peut entraîner 

des blessures graves, décès ou perte / dommages à la propriété.

WARNING! 

This device must be protected by a circuit breaker (20A max).

ATTENTION!

 Cet appareil doit être protégé par un disjoncteur (20A max.)

WARNING! 

Ground this device in accordance with the National Electric 

Code (NEC) requirements. DO NOT rely solely upon the yoke plate’s 

contact with a metal wallbox for adequate grounding. Use the device’s 

ground wire to make a secure connection to the safety ground of the 

electrical system.

ATTENTION! 

Cet appareil doit être en conformité avec le Code national de 

l’électricité (NEC). Ne comptez pas uniquement au contact de la plaque 

avant avec un boîtier mural métallique pour la mise à la terre adéquate. 

Utilisez cet appareil à la terre de l’appareil pour établir une connexion 

sécurisée au système électrique.

IMPORTANT! 

This device must be installed by a licensed electrician in 

accordance with all national and local electrical codes.

IMPORTANT! 

If you are unsure about any part of these instructions, 

consult a qualified electrician.

IMPORTANT!  

Use this device only with copper or copper-clad wire. Do 

not use aluminum wiring. This product has not been approved for use with 

aluminum wiring.

IMPORTANT! 

Using this product in a manner other than outlined in this 

document voids your warranty. Further, Control4 is NOT liable for any 

damage incurred with the misuse of this product. See “Troubleshooting.”

IMPORTANT! 

Do NOT use a power screwdriver to install this device. If you 

do, you may overtighten the screws and strip them. Also, overtightening 

the screws may interfere with proper button operation.

IMPORTANT! 

This is an electronic device with intricate components. 

Handle and install with care!

IMPORTANT! 

When used in conjunction with an Auxiliary Keypad 

(C4-KA-xx), the wire connecting the Auxiliary Keypad to the Configurable 

Keypad must not exceed 45 m (150 ft.) at 120V AC, and 30 m (100 ft.) at 

277V AC.

Installation instructions

Ensure that the location and intended use meet the following criteria:

• 

When replacing a traditional 3-way switch, refer to the “Two-Location” 

sample wiring configurations provided in the appropriate load control 

device installation guide.

• 

Install in accordance with all national and local electrical codes.

• 

The range and performance of the wireless control system is highly 

dependent on the following: (1) distance between devices; (2) layout 

of the home; (3) walls separating devices; and (4) electrical equipment 

located near devices.

Turn off the local electrical power by either switching off the circuit breaker or 

removing the fuse from the fuse box. To ensure the wires do NOT have power 

running to them, use an inductive voltage detector.

Supported model

• 

C4-KC120277  Wireless Configurable Keypad

Introduction

The Control4® Configurable Keypad is intended for use in a Control4 system. It 

installs in a standard wallbox using typical wiring standards and communicates to 

the Control4 system using a wireless connection.

Box contents

• Configurable 

Keypad 

• 

Keycap Button Kit

• Wire 

nuts

• Warranty 

card

• 

Configurable Keypad Installation Guide

 (this document)

• 

Keypad Button Installation Guide

Specifications

The specifications are described below.

Model number

C4-KC120277-xx

Power requirements

120-277V AC +/-10% 50/60 Hz 

36-48V DC

This device requires a neutral AC connection.

Power consumption

120V: 350mW

277V: 540mW

36V DC: 430mW

Environmental

Operational temperature

0 to 40 ˚C (32 to 104 ˚F)

Humidity

5% to 95% non-condensing

Storage

-20 to 70 ˚C (-4 to 158 ˚F)

Miscellaneous

Control communications

Zigbee, IEEE 802.15.4, 2.4 GHz, 15-channel 
spread spectrum radio

Wallbox volume

4.75 cubic inches

Weight

0.05 kg (0.12 lb.)

Shipping weight

0.08 kg (0.18 lb.)

Configurable Keypad  

Installation Guide

Copyright ©2021, Wirepath Home Systems, LLC. All rights reserved. Control4 and SnapAV and 
their respective logos are registered trademarks or trademarks of Wirepath Home Systems, LLC, 
dba “Control4” and/or dba “SnapAV” in the United States and/or other countries. 4Store, 4Sight, 
Control4 My Home, Snap AV, Araknis Networks, BakPak, Binary, Dragonfly, Episode, Luma, 
Mockupancy, Nearus, NEEO, Optiview, OvrC, Pakedge, Sense, Strong, Strong Evolve, Strong Vers-
abox, SunBriteDS, SunBriteTV, Triad, Truvision, Visualint, WattBox, Wirepath, and Wirepath ONE 
are also registered trademarks or trademarks of Wirepath Home Systems, LLC. Other names and 
brands may be claimed as the property of their respective owners. All specifications subject to 
change without notice.

200-00309-G 20210409MS

Reviews: