background image

Protected under U.S. Patents 7,335,845, 7,106,261 and licensed under U.S. Patents 

5,905,442 and 5,982,103

About this Document

©2011 Control4. All rights reserved. Control4, the Control4 logo, the Control4 iQ logo

and the Control4 certified logo are registered trademarks or trademarks of Control4 

Corporation in the United States and/or other countries. All other names or brands may 

be claimed as property by their respective owners. Pricing and specifications subject to 

change without notice. 

 

Part Number: 200-00164 Rev H  3/04/2011

Recycling

For information about Control4’s recycling program, go to: 

www.control4.com/recycling.

Warranty

Limited 2-year Warranty. Refer to http://www.control4.com/warranty.

Third-Party Trademarks

Libertas

Libertas Firmware copyright statement for Touch Screens 6/26/09

Copyright (c) 2006, One Laptop per Child and Marvell Corporation.

All rights reserved.

 

Redistribution.  Redistribution and use in binary form, without modification, are permitted 

provided that the following conditions are met:

 

* Redistributions must reproduce the above copyright notice and the following disclaimer   

in the documentation and/or other materials provided with the distribution.

* Neither the name of Marvell Corporation nor the names of its suppliers may be used 

to endorse or promote products derived from this software without specific prior written 

permission.

* No reverse engineering, decompilation, or disassembly of this software is permitted.

* You may not use or attempt to use this software in conjunction with any product that is 

offered by a third party as a replacement, substitute or alternative to a Marvell Product 

where a Marvell Product is defined as a proprietary wireless LAN embedded client solu

-

tion of Marvell or a Marvell Affiliate.

 

DISCLAIMER.  THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND 

CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUD

-

ING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL 

THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, 

INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES 

(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR 

SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) 

HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, 

STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING 

IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE 

POSSIBILITY OF SUCH DAMAGE.

GNU

GNU GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING, DISTRI

-

BUTION AND MODIFICATION (Section 3.b.)

You may copy and distribute the Program (or a work based on it, under Section 2) in 

object code or executable form under the terms of Sections 1 and 2 above provided that 

you also do one of the following: 

 Accompany it with a written offer, valid for at least three years, to give any third party, for 

a charge no more than your cost of physically performing source distribution, a complete 

machine-readable copy of the corresponding source code, to be distributed under the 

terms of Sections 1 and 2 on a medium customarily used for software interchange.

The complete text for this license is available on the Control4 web site at: http://www.

control4.com. 

At Security, select 

None

WEP 64

WEP 128

, or 

WPA

. At Password, type the 

password on the keyboard that appears. Press 

Done

.

Select 

Connect

. Notice that the IP settings change. The IP address is set to 

DHCP by default. 

(Optional) If you need to set a static IP address instead, complete the following 

steps:

• 

On the Network page, press 

Static

.

• 

Select each box one at a time and type the address: 

IP Address

Subnet 

Mask

Default Gateway

Preferred DNS

, and 

Alternate DNS

. When the 

keyboard appears, type the address, and then press 

Done

.

Press 

OK

 to return to the Network page. You can now connect to a Control4 

Director running on a Control4 device on the network.

Press 

OK

.

e.

f.

g.

h.

3

5

Align and slide the back of the Touch Screen into the power box. The Touch Screen is 

magnetic and should snap right into place.

(Optional) To secure the Touch Screen inside the power box, remove the tape  

covering the bottom security pin (see Figure 9) before attaching the Touch Screen to 

the power box. 

Note the pinhole on the bottom underside of the Touch Screen’s faceplate. If you ever 

need to remove the Touch Screen from the wall, do the following:

Figure 8.  Ethernet Connection

Black and White Wires

a.
b.

Locate the small pinhole on a tab (right side) underneath the Touch Screen. 

Insert a paper clip into the hole (about 1/4”). With both hands, lift the Touch 

Screen from the bottom of the screen toward you to remove it (see Figure 9).

Figure 9.  Touch Screen Pin and Pinhole 

AC Power Connection

. The steps below represent a typical U.S. installation.  

Connect wires to the AC power source for the Touch Screen according to your  

national and local electrical codes. Your installation may require alternative wires and 

the use of a terminal block.

a.

b.

c.

Thread the power cable through the bottom back hole of the wall box to the  

terminal (Figure 7). Remove the tab covering the hole first.

Using the orange wire nuts (shipped in the box) connect the white-to-white wire 

and the black-to-black wire, and then cap each one with a wire nut. Strip the wire 

to 1/4” if necessary.

Cap the ground wire from the wall if you are using a plastic wall box. Attach the 

ground wire to the wall box when using a metal wall box.

d.
e.

Align and bend the wires carefully to fit them inside the wall box.

Align and carefully slide the power box into the wall box.

Figure 7. AC Power Connection

Regulatory Compliance

FCC/Industry Canada

 

FCC ID: R33D2 (InfinityEdge 5” In-Wall Touch Screen); R33D3 (InfinityEdge 7” In-Wall 

Touch Screen)/Canadian IC: 7848A-D2 (InfinityEdge 5” In-Wall Touch Screen); 7848A-D3 

(InfinityEdge 7” In-Wall Touch Screen) 

This device complies with Part 15 of the FCC Rules Sub-Part B and C and with

Canada ICES-003 and RSS-Gen. Operation is subject to the following two

conditions: (1) this device may not cause harmful interference, and (2) this device

must accept any interference received, including interference that may cause

undesired operation.

8

When your Touch Screen is physically installed and appears on the home network, 

you can add and configure it to the Control4 System using the Composer Pro 

software. See the 

Composer Pro User Guide

 for information about how to add and 

identify the Touch Screen to the Control4 System.

IMPORTANT!  

Any changes or modifications not expressly approved by the 

party responsible for compliance could void the user’s authority to operate this 

equipment.

Australia/New Zealand Compliance

• 

AS/NZS CISPR 22:2006

Installation

WARNING!

  For the location where you are installing the Touch Screen, switch off 

the circuit breaker or remove the fuse from the fuse box.

Avertissement! 

Pour l’endroit où vous installez l’écran tactile, coupez le disjonc

-

teur ou enlevez le fusible de la boîte de fusible.

Warnung!

 Für die Position, in der Sie die Berührungseingabe anbringen, den 

Circuit breaker ausschalten oder die Sicherung vom Sicherung Kasten entfernen.

IMPORTANT!

  When cutting the opening for the wall box, DO NOT cut the open

-

ing too large. Be conservative and cautiously enlarge it as needed.

Important! 

 En coupant l’ouverture pour la boîte de mur, ne coupez pas 

l’ouverture trop grande. Soyez conservateur et agrandissez-avec précaution la 

comme nécessaire.

Wichtig!

 Wenn Sie die öffnung für den Wandkasten schneiden, schneiden Sie 

NICHT die große öffnung zu. Seien Sie konservativ und vergrößern Sie es vorsi

-

chtig, wie gebraucht.

IMPORTANT!

  Before you can complete these instructions below, you must have 

a Control4 5” or 7” Touch Screen wall box installed according to the documenta

-

tion provided in the wall box kit. See “Accessories” for details.

Important! 

 En coupant l’ouverture pour la boîte de mur, ne coupez pas 

l’ouverture trop grande. Soyez conservateur et agrandissez-avec précaution la 

comme nécessaire. Voyez que <<Accessories>>.

Wichtig!

  Bevor Sie diese Anweisungen durchführen können, müssen Sie ein 

Control4 7 haben“ der Berührungseingaben- Wandkasten, der entsprechend den 

Unterlagen angebracht wird, die in den Wandkasteninstallationssatz bereitgestellt 

werden. Sehen Sie daß “Accessories.”

Network Options

• 

PoE

: The Ethernet network connection is provided through the PoE Injector. No  

additional wiring is needed.

• 

Standard Ethernet Connection

: Connect the Touch Screen to one of the RJ-45 

LAN ports on the gateway/router using the RJ-45 Ethernet cable.  

• 

WiFi Connection

: The internal WiFi antenna will communicate with the LAN’s WAP. 

If the LAN has a WAP set up, no additional wiring is needed.

Power Configurations

• 

AC Power

. AC power is used to power the Touch Screen when using an Ethernet 

or WiFi network connection.

• 

Power Over Ethernet (PoE)

. PoE is used to power the Touch Screen when using 

an Ethernet or WiFi network connection.

Power Cable

Wall Box

Power Box

Ethernet Connection

(WiFi only) Connect to a WAP on the Touch Screen (see Figure 10):

After initialization, press and 

hold the large red 4 on the 

center of the Touch Screen 

to enter the configuration 

screen.

Press the Network button on 

the Touch Screen configura

-

tion page. The network con

-

figuration screen displays.

Under Wireless, select  

Enable

. If you don’t see the 

network you want, select 

Other

.

To protect the screen’s display: Use one of the screen-saver options available from 

the 

More

 > 

Settings

 > 

Screen Saver

 page.

6

a.

b.

c.

d.

Figure 10. Wireless Configuration

Back View

Figure 6.  Back View of InfinityEdge 5” or 7” In-Wall Touch Screen   

and Power Box

1

2

1
2

Wireless Connection

: Hot (H) uses Black wire; Return (R) uses White wire.

RJ-45 port for Ethernet Connection

: Ethernet port available for either a standard 

Ethernet source that provides network communication only OR a PoE source that 

provides power to the device and network communication.

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to radio or televi

-

sion reception, which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Display

: 5” or 7” viewing area, Touch Screen with 800 x 480 resolution.

Shortcut buttons (4)

: For custom programming; to initiate an action or sequence of 

actions. Use Composer Pro or Composer HE to configure these buttons.

Touch Screen Removal

: Small hole located under the Touch Screen to remove the 

Touch Screen from the wall.

Front dimensions

. 5” Touch Screen (H x W x D):  3.15” x 4.8 x 0.9” (80mm x 122mm 

x 23mm); 7” Touch Screen (H x W x D): 4.6” x 6.9 x 0.9” (117mm x 175mm) x 23mm)

Wall box dimensions

. 5” or 7” Touch Screens (H x W x D): 2.7” x 4.1” x 2.4”  

(68mm x 104mm x 61mm)

Power box dimensions

. 5” or 7” Touch Screens (H x W x D): 2.8” x 4.5” x 1.8” 

(71mm x 114mm x 46mm)

1
2

3

Connect the Control4 PoE Injector to a power source, for example, an AC outlet, 

using the power cord (provided with the unit). 

Connect one of the RJ-45 LAN ports on the gateway/router/switch to the PoE 

Injector’s LAN port using the RJ-45 Ethernet cable. 

Connect the PoE Injector’s PWR LAN-OUT port to the RJ-45 Ethernet cable that 

will be connected to the Touch Screen. 

Pull the Ethernet cable through the top back hole of the wall box to the Ethernet 

connector on the top back of the power box, and then connect it (see Figure 8).

Align and carefully slide the power box into the wall box. Unless the Touch 

Screen is in the power box, it doesn’t pull any power.

a.

b.

c.

d.

e.

Power Over Ethernet (PoE) Connection

. Install a PoE Injector (sold separately) or 

switch, and then connect the PoE Injector to the power and network. Connect to the 

power box. The steps below describe how to install a Control4 PoE Injector.

Prepare the plastic power box for installation into the wall box by inserting either the 

Ethernet cable or the AC power cable into the power box (see Figures 7 and 8).

1

Secure the power box into the wall box using the screws provided. 

Note

: Overtighten

-

ing power box screws could result in a poor connection between the Touch Screen 

and the power box.

2

Speaker

Insert paper clip here to 

remove Touch Screen

Security pin

Restore the Touch Screen to Factory Default

Press and hold the red 

button in the top left corner of the screen upon start up, and  

follow the instructions presented on the screen to initiate the factory restore process and 

to reset the Touch Screen to the factory default settings.

At Network Name, select to add the SSID or wireless network when the keyboard 

appears. Select 

Done

.

Reviews: