background image

4

FEATURES

OPERATION

To open or close the door simply press

the  hand  held  transmitte

r or t

he

 wall

mounted  transmitter

 for two

 

seconds

During an open

 or close cycle the door

can be stopped

 by pressing the button 

while the door is

 in motion.

The next actuation will move

 the door

in  the  opposite  direction.

SECURITY CODE STORE

The  Shed Master  Garage  Door  Opener

uses  state  of  the  art  technology  in

storing  your  selected  transmitter 

security  code.  Up  to  six  unique

transmitters can be stored in the openers

memory, plus one dipswitch unit and an

entry keypad.

WEATHERPROOF DESIGN

The opener’s control board is housed in

a weather-proof enclosure rated to IP24.

This  offers  protection  from  rain 

however the unit should not be sprayed

by  a  hose  or  any  other  water  carrying

device.

AUTOMATIC LIMITS

POSITIONING

The  limits  system  automatically 

calculates  the  doors’ travel  limits  and

stores  it  in  memory.  If  the  door  is

moved manually within the travel limits

during a power failure, it will recognise

this once the power is restored and stop

at the correct limit position if the door is

activated.

INTELLIGENT FORCE MARGIN

SAFETY OBSTRUCTION SYSTEM

While  the  door  is  performing  a  close

cycle,  should  it  hit  an  obstacle  or  be

restricted  in  some  manner,  it  will

automatically  reverse.  The  amount  of

force the door should encounter before

reversing  is  automatically  adjusted  by

the  doors  control  system  during  the

initialisation  of  the  automatic  door

opener.  The  door  will  also  stop  if

restricted  whilst  opening.  The  Safety

Obstruction Force should be checked at

least  once  a  month.  See  installation

manual for instructions.

LOCKABLE CONTROL PANEL

The  control  panel  can  be  locked  and

disabled  to  prevent  tampering.  This  is

useful if the opener is to be mounted on

an exposed carport or a perimeter door.

Locking the control panel will prevent

operating  the  door  via  the  Operate 

button,  re  profiling,  clearing  limits,

clearing  transmitters,  changing  force

margins, and coding transmitters.

OVER LOAD INDICATOR

When  the  maximum  opening  and 

closing  capacity  of  the  opener  is

exceeded an audible beeper will sound

to  indicate  that  an  overload  has

occurred.

PHOTO ELECTRIC BEAM

(OPTIONAL)

The  opener  has  an  input  for  a  photo

electric beam to be connected for extra

safety  protection  and  use  of  the  auto

close mode.

MANUAL OPERATION

The  opener  is  equipped  with  a  unique

patented manual disengaging device. If

the power to the opener is disrupted for

any  reason  the  door  can  be  put  into

manual  mode  by  pulling  down  on  the

string handle, then releasing. This will

allow you to manually open or close the

door.  When  power  is  restored,  by

pulling  down  on  the  string  handle  and

releasing,  the  opener  is  put  back  into

automatic mode.

SECURITY LOCK  FOR  MANUAL

RELEASE HANDLE (OPTIONAL)

For  added  security  the  manual  release

handle  can  be  locked  out  or  disabled.

This  is  ideal  if  the  opener  is  to  be

mounted  on  a  perimeter  door  in  an

exposed carport.

©Copyright 2006 B&D Doors

Thank  you  for  purchasing  the  B&D 

Controll-A-Door® ShedMaster Automatic 

Rolling Garage Door Opener. This opener 

is  designed  to  suit  vertical  operating 

continuous  curtain    rolling  doors.  The 

components  and  materials  used  in  this 

opener  are  of  the  latest  technology  and 

highest quality. Listed below are some of 

the many features.

Summary of Contents for Controll-A-Door ShedMaster

Page 1: ...s to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please...

Page 2: ...4 15 16 17 18 19 20 B D Doors to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions...

Page 3: ...s vital for the safety of persons to follow all instructions Failure to comply with the following Safety Rules may result in serious personal injury and or property damage The unit is rated to IP24 ho...

Page 4: ...should be checked at least once a month See installation manual for instructions LOCKABLE CONTROL PANEL The control panel can be locked and disabled to prevent tampering This is useful if the opener i...

Page 5: ...factors wind etc affect the operations of the door opener PLUS button green can be used during installation to set the open limit position Pressing this button will move the door in the open direction...

Page 6: ...DE BUTTON BLACK 5 CODING LED RED 6 SET BUTTON ORANGE 7 OPERATE BUTTON BLUE 8 FORCE MARGIN SET BUTTON 9 PLUS BUTTON FOR LIMITS SETTING FORCE MARGIN 10 OPEN LIMIT LED GREEN 11 MINUS BUTTON FOR LIMITS SE...

Page 7: ...N FLAT WASHER I D 3 16 x 1 2 2 2 S R E V O C R A B G N I K C O L 1 L A U N A M N O I T A L L A T S N I Copyright 2006 B D Doors TRANSMITTER B D CONTROLL A DOOR SHEDMASTER DRIVE UNIT COLLAR KIT 1 SELF...

Page 8: ...ck or bind in the guide tracks The ideal operational effort in raising or lowering the door should not exceed a force of 10kg 22 lbs Make sure that all door locks ropes chains etc are either released...

Page 9: ...hand door mounting bracket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork If the gear does not rotate the manual mode has to be selected T...

Page 10: ...cure the curtain to drum wheel using self drilling screws two on each end The screws should be at least 90 degrees apart FIG 7 Copyright 2006 B D Doors DRUM WHEEL 5 1 MOUNTING THE TRANSMITTER BRACKET...

Page 11: ...OOR LIMITS POSITIONS The door limit positions can be deleted for new positions by following the steps below 1 Press and hold the Minus button Fig 10 for six 6 seconds until you hear three beeps and th...

Page 12: ...1 Press and hold the Force Margin Set button Fig 11 2 While holding down the Force Margin button press the Plus button Each press increases the force margin in both directions The Open Limit LED will...

Page 13: ...ter the code is now set 10 1 SETTING ENTRY KEYPAD TRANSMITTER CODE 1 Make sure that the battery is set in the Keypad Transmitter 2 Press the Code Set button on the opener the Code Set LED will illumin...

Page 14: ...e The door may move uncontrollably if the spring tension is weak or not set properly or the door is unbalanced If this occurs do not use the door and contact your installer for service The manual rele...

Page 15: ...de Codes a transmitter button for OPERATE function Force Margin Set Plus Increases the obstruction force margin setting Force Margin Set Minus Decreases the obstruction force margin setting Force Marg...

Page 16: ...No of CODE COMBINATIONS Over 3 86 Billion Codes TRANSMITTER BATTERY 2 x 3V Type 2032 Button Cell DEFAULT SETTINGS AND SPECIFICATIONS 16 Note 1 The maximum continuous curtain residential roll up door...

Page 17: ...tracks Possible obstruction in the doorway Increase force margin setting See Step 8 3 on page 13 Or re calculate force margin See Step 8 6 on page 13 Remove obstruction Door operates from drive unit O...

Page 18: ...ORMER TDB 72 01 KIT 72VA 62079 RATCHET TIMING ASSY 62078 POWER CORD A S 1 5M 2P1R 62081 FELT 21 X 29 TERMINAL BLOCK 500 02DS 2 POS CAP POLYFILM 0 1UF K X2 275 VAC HEX SERRATION HEAD SCREW M8X16 TAPTIT...

Page 19: ...for any service call made by B D or an Authorised Distributor where such a call is made for the purpose of adjustment as described in the Manufacturers Written Instruction Manual and not for rectifica...

Page 20: ...difications or repairs made or attempted to be made by any unauthorised person vii Faulty electrical wiring of structures to which the Opener is affixed viii Radio or other electronic interference inc...

Reviews: