Pre-installation Preparation (cont.) 

Pre-installation Alignment: 

Before anchoring the cabinets to the floor, we recommend laying out the lane and testing 
alignment. 

Place the cabinets in their approximate end location and connect the 2 conductor cable 
inside of the primary cabinet to the end in the secondary cabinet. Plug in the primary 
cabinet to AC voltage to power up the lane. 

Inside of the primary cabinet, there is a series of 7 total photo cell sensors. Each of these 
sensors is equipped with two LED’s on the rear. One of them is green and should always 
be lit. The other should be solid orange while the beam is uncrossed and off while the 
beam is crossed.  

If the orange LED is blinking in any case, you will need to adjust the sensor alignment, 
shift the cabinets so that they are straight to each other, or shim the cabinets so that they 
are level. 

See the sensor alignment section of this manual

 for advice on how to ensure the 

transmitter’s light reaches the receiver properly. 

Glass Information: 

To conceal the sensor array, a sheet of tinted glass is to be installed onto the front panels. 
This glass can create a dispursion effect to the sensor beams. It is suggested that the 
lane’s function is tested with the glass in place to ensure alignment is sufficient for the 
final installation.  

Security Begins With Controlled Access

1636 W. 130th Street, Brunswick, OH 44212

Toll Free Phone: (800) 942-0829 | Fax: (800) 942-0828 / Phone: (330) 273-6185 | Fax: (330) 273-4468

8

Summary of Contents for BE800-R

Page 1: ...l after installation If an installation is done by a construction company or outside installer please pass this book along to the end user This book is required for maintenance troubleshooting and rep...

Page 2: ...ons 10 Sensor Alignment 12 Sensor Designations 13 Wiring Legend 14 Wiring Diagrams 15 Overview of the Access Window 17 Device Settings of the Beacon Series 19 Warranty Information 21 Security Begins W...

Page 3: ...nsor zones mentioned previously a third sensor zone exists for crawl through detection If anyone attempts to crawl through the lane under the standard sensor zones the third sensor zone detects them a...

Page 4: ...econdary From the factory each cabinet in an array is preconfigured to the requested operation and layout Each lane has two directions of passage each of which can be configured for controlled passage...

Page 5: ...is necessary in order to operate the secondary cabinet It will be necessary to provide conduit access between the two cabinets However only the primary cabinet requires 100 240VAC The secondary cabin...

Page 6: ...binet The lids are secured with a lock on the front and hooks on the back In order to remove the lid unlock the front side with the provided keys Then pull the lid forward from the back and lift up to...

Page 7: ...g it out of the floor plate Although it should not be necessary the sensors can be disconnected from their cables Each sensor is equipped with an M8 euro style quick disconnect cable These can be disc...

Page 8: ...d off while the beam is crossed If the orange LED is blinking in any case you will need to adjust the sensor alignment shift the cabinets so that they are straight to each other or shim the cabinets s...

Page 9: ...Concrete Anchor Instructions Security Begins With Controlled Access 1636 W 130th Street Brunswick OH 44212 Toll Free Phone 800 942 0829 Fax 800 942 0828 Phone 330 273 6185 Fax 330 273 4468 9...

Page 10: ...wise operation will be inconsistent 3 If necessary move cabinets out of the way Drill four 3 8 holes 4 deep per cabinet and remove all concrete dust from the holes 4 Place cabinet in the correct locat...

Page 11: ...lignment instructions and test lane to ensure operation is satisfactory before replacing the front panels onto the cabinets 9 Install the sheets of glass by remove the two screws holding the glass cli...

Page 12: ...l will allow for some range of motion up and down The sensors can also be tilted on the brackets themselves to provide a left to right alignment adjustment Simply loosen the screws holding the bracket...

Page 13: ...ed Sensor Zone 2 does the same thing as zone 1 but in the opposite direction The sensor zones have another function as well On free flow mode when the sensor zone for the appropriate direction is actu...

Page 14: ...Wiring Legend Security Begins With Controlled Access 1636 W 130th Street Brunswick OH 44212 Toll Free Phone 800 942 0829 Fax 800 942 0828 Phone 330 273 6185 Fax 330 273 4468 14...

Page 15: ......

Page 16: ......

Page 17: ...ode is active the display screen will show DM in the top left corner That being said it is possible to stray from the device mode settings In the selected device type section of the access window DM T...

Page 18: ...ll need to access system mode to run the program in this fashion Holding the key while pressing up and down allows you to change between system mode and device mode A third mode which will display TRM...

Page 19: ...rnally Enabling this allows the turnstile to ignore access control from allowing too many users pass through the turnstile Disabling it allows access control to hold the direction open 0 means the one...

Page 20: ...ither direction is active In facilities where users drag objects low to the ground behind them frequently such as gyms with rolling luggage it may be beneficial to disable this setting A value of 0 is...

Page 21: ...e Seller transportation charges prepaid Replaced or repaired goods will be redelivered freight repaid to the address of Buyer shown hereon Except for the Warranty contained herein there shall be no ot...

Reviews:

Related manuals for BE800-R