background image

GB

20

Lighting Instructions

Possible causes of mal-
functions and how to rectify 
them

Poor draft in the stove after new installation

It is difficult to light the fire and the fire dies 

after a short time 

Abnormal amounts of soot form on the glass

Smoke odour around the stove for periods

Painted parts have become discoloured

•   Check the dimensions of the chimney so that they correspond 

to the ones stated in the installation instructions.

•   Check that there is nothing in the chimney to restrict the 

smoke and that no nearby buildings or trees affect the winds 
around the chimney.

This can occur when wind blows down the chimney and most of-
ten occurs when the wind is from a particular direction. Another 
reason could be that the hatch was opened when there was a lot 
of flame.

If painted parts have discoloured it is due to excessive tempera-
ture in the firebox. The reason for the excessive temperature 
can be that the maximum amount of wood has been used or that 
inappropriate fuel has been used (for example building waste, 
large quantities of finely chopped off cuts). The warranty does 
not cover damage of this type. If a problem occurs that you can-
not rectify yourself, contact the dealer or a chimney sweep. 
We hope that these lighting tips give you enjoyable, economical 
and problem free use of your Contura stove.

•  Check that the wood is sufficiently dry.
•   Too great a negative pressure in the house, for example when 

using a kitchen extractor fan or other mechanical ventilation. 
Open a window near the hearth before lighting the fire. Also try 
lighting some newspaper and holding it up inside the firebox to 
get the draft going.

•   The supply air duct from outdoors can be partially or totally 

blocked. Remove the hose and try test lighting with combus-
tion air from the room.

•  Check that the combustion air damper is open.
•   The smoke outlet of the stove may be blocked with soot, which 

can occur after sweeping.

  Lift the smoke baffle out and check.
•   Finally, go through the lighting instructions again.
   Perhaps the amount of kindling was too small and therefore 

the base embers were too weak and cold to light the next load 
of wood.

There is always a certain amount of soot on the glass and this is 
added to with each lighting. Soot on the glass is caused by three 
things:
•   The wood is damp, which causes poor combustion and gener-

ates a lot of smoke as a result.

•   Too low temperature in the firebox, which causes incomplete 

combustion and poor draft in the chimney.

•   Handling is not correct, for example the hatch was not in the 

lighting position for 5-10 min.

   Check the moisture content of the wood, ensure that you have 

good base embers and go through the lighting instructions one 
more time.

Sweeping

Sweeping the chimney ducts and chimney connections should 
be carried out by a chimney sweep. Sweep the stove by scrap-
ing and/or brushing. A soot vacuum cleaner is most appropriate 
however. If a chimney fire occurs or is suspected, the combus-
tion damper and the door must be closed. If necessary, contact 
the fire brigade to extinguish it. The chimney must always be 
inspected by a chimney sweep after a chimney fire.

Warning 

•   During operation, the surfaces of the stove become very 

hot and can cause burn injury if touched.

•   Be aware of the strong heat radiated through the hatch 

glass.

•  Placing flammable material closer than the safe distance 
indicated may cause a fire.
•   Pyre lighting can cause quick gas ignition with the risk of 

damage to property and personal injury.

Contura reserves the right to change dimensions and pro-
cedures described in these instructions at any time without 
special notice. The current edition can be downloaded from 
www.contura.eu  

NIBE AB· Box 134 · 285 23 Markaryd · Sweden
www.contura.eu

811064 BAV SE-EX C750/780-3
2011-11-29

Summary of Contents for 750

Page 1: ... Approved Document J Should any conflict apply between these instructions and the original manufacturers instructions then the most stringent advice must apply Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registere...

Page 2: ...ossibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury STOVE PERFORMANCE Refer to the manufacturer s main instruction manual for details of the stove s performance PREPARATORY WORK AND SAFETY ...

Page 3: ...230 mm x 230 mm Remedial action should be taken if required seeking expert advice if necessary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted i...

Page 4: ...ey to be swept through the appliance Hearth The hearth should be level and able to accommodate the weight of the stove and its chimney if the chimney is not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible hearth of a size and construction that is in accor dance with the provisions of the current Building Reg...

Page 5: ...e the diameter of the flue to the minimum required 150 mm section of the chimney or liner All joints in the connection between the stove and the chimney must be made gastight using fire cement and where necessary fire proof rope infill Means should be made for sweeping the entire length of the flue be that through the appliance or by suitable sweeping hatch in the flue Commissioning and handover E...

Page 6: ...the fire go out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean at all times IMPORTANT NOTES General Before lighting the stove check w...

Page 7: ...the chimney will require sweeping after a month of continuous operation This is a precaution to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep through the stove the installer will have provided alternative means such as a soot door After sweeping the c...

Page 8: ...quires a permanent and adequate air supply in order for it to operate safely and efficiently In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not under any circumstances be shut off or sealed USER OPERATING INSTRUCTIONS Please read the important noti...

Page 9: ... an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales thi...

Page 10: ...d with a mechanical stop to prevent closure of the air control vent beyond the 28 open position when sold into smoke control areas The Contura i4 series must be fitted with a mechanical stop to prevent closure of the air control vent beyond the 30 open position when sold into smoke control areas The Contura i5 series must be fitted with a mechanical stop to prevent closure of the air control vent ...

Page 11: ......

Page 12: ...811142 BAV GB 7 2014 03 03 NIBE AB Box 134 285 23 Markaryd Sweden www contura eu ...

Page 13: ...C 780 www contura eu Installation Instructions ...

Page 14: ...e aspect of our vision to be a company of the future setting high quality standards regarding the environment Certification number 378 001 www contura eu EC Declaration of conformity Manufacturer name NIBE AB NIBE STOVES address Box 134 Skulptörvägen 10 SE 285 23 Markaryd Place of manufacture Markaryd Sweden PrODuct Product type Stove fired by solid fuel type designation Contura 780 Standard EN 13...

Page 15: ...ad how to best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the risk of damage ...

Page 16: ...uitable technicians Building application These main insructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local authority for advice regarding building regulations Before installing a stove or erecting a chimney it is necessary for you to make a building application permission to your local authority Structural sup...

Page 17: ...connection sleeve is 150 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and a suitable cross section area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney Maximum horizontal fl...

Page 18: ...be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor is sealed using jointing compound A 1 m length of condensation insulated ducting for combustion air is available as an accessory Through the external wall Indirect air supply through the external wall Through...

Page 19: ...nces for the stove When connecting to a steel flue also note the safety distance requirements of the flue The safety distance between an un insulated flue and a combustible part of the building should be at least 450 mm Installation distances WHEN INSTALLING TURNTABLE OPTION the following installation distances do not apply See the separate installation instructions for turntable 631 400 278 278 2...

Page 20: ...Y Remove loose parts before the insert is placed on its back 3 4 Do not tighten the screws before the sides and back are installed Do not tighten the screws until the stove has been raised again 2 1 Installing C 780 ...

Page 21: ...GB 57 ASSEMBLY Clean the side glass thoroughly before installing the side panels 5 8 6 7 1 2 ...

Page 22: ... must be placed on the inside of the cover on the pillar Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time ...

Page 23: ...VAL How to remove the hearth surround Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order 2 1 ...

Page 24: ...u Contura reserves the right to change colours materials dimensions and models at any time without special notice Your dealer can give you the most up to date information Stoves shown in brochures may have extra equipment 811079 IAV SE EX C780 8 2012 06 14 ...

Page 25: ...Lighting Instructions C 750 C 780 www contura eu ...

Page 26: ...h damage Important NOTE The left hand handle that controls the grate disc must be closed during lighting 1 Open the control for the combustion air fully 2 Insert paper or firelighters and about 2 0 kg of thinly chopped kindling into the firebox Stack the wood crosswise 3 Light the fire 4 Set the hatch to the lighting position that is with the lower hook against the lock roller to create a sufficie...

Page 27: ...bers The ash must be stored in a fireproof container with a lid for at least one week before being disposed of The grate and other cast iron components in the firebox can be cleaned using a wire brush It is important from a combustion point of view to check gas kets as worn gaskets hinder combustion when the stove draws extra air Painted parts on the stove can be cleaned using a damp cloth with a ...

Page 28: ...the room Check that the combustion air damper is open The smoke outlet of the stove may be blocked with soot which can occur after sweeping Lift the smoke baffle out and check Finally go through the lighting instructions again Perhaps the amount of kindling was too small and therefore the base embers were too weak and cold to light the next load of wood There is always a certain amount of soot on ...