Technical specifications
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3–9 kW
Efficiency, up to . . . . . . . . . . . . . . . . . . . . . . . . . .80%
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .290 kg
Stove width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .552 mm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526 mm
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1250 mm
Connecting sleeve (internal dia.). . . . . . . . . . .Ø150 mm
Type approved in accordance with:
European standard EN-13240 class 1
Swedish environmental and quality certification,
“P marked” cert. no. 22 03 07
Swedish type approval, cert. no. 0887/99
Norwegian standard NS 3059, certificate no. 043-088
German standard DIN 18.891, RO-91 99 84
Danish standard 887-1,ID nr 598
General information
This folder contains instructions on how to assemble and install
stoves in the Contura 480. The stove also comes with comprehen-
sive Lighting and Maintenance Instructions. Please take time to
read all this information carefully and keep it in a safe place for
future reference.
Contura 480 stoves have been type-approved in Sweden for con-
nection to a chimney which can withstand flue gas temperatures
of 350 °C. The connecting sleeve has an external diameter of 150
mm.
To ensure proper combustion, sufficient air must be supplied to
the stove from outdoors.
A convector fan is available as an optional extra for your stove. If
you require further advice and instructions concerning the instal-
lation of a wood-burning stove, we recommend that you contact
your local chimney sweep or the relevant authority in your area.
Building permission
It may be necessary for you to apply for building permission from
your local planning authority be fore installing a stove or erecting
a chimney. Before start ing installation work, make sure that you
check which regulations apply.
Structural support
Check to make sure that the floor is strong enough to support the
weight of the stove and chimney. If you intend to locate the stove
on standard wooden floor joists, contact a professional builder
to make sure that the construction will withstand the load. If the
total weight of the stove and chimney together does not exceed
400 kilos, it is not usually necessary to reinforce the joists
Floor plate
To protect the floor from sparks and falling embers the stove
must stand on a non-combustible surface which extends at least
300 mm in front of the stove and 100 mm along each side. As
other statutory requirements apply in some countries, we recom-
mend that you consult the relevant authority or an authorised
chimney-sweep in your area.
Chimney
The draught in the chimney must generate a neg ative pressure
of at least 12 Pa. The draught is affected both by the length and
cross-sectional area of the chimney, and by how well sealed the
construction is. The shortest recommended chimney length is 3.5
metres. The cross-sectional area of the chimney must be approx-
imately 150–200 cm² (140–160 mm in diameter).
Make sure that there are no gaps around soot hatch es and flue-
pipe connections.
Remember that the draught is reduced in flues with sharp bends
or horizontal sections. A horizontal flue length of up to 1.0 metre
is permissible, provided that the vertical flue is at least 5.0 met-
res in height.
It must be possible to clean the flue throughout its entire length,
and the soot hatches must be easily accessible.