21

PRODUCT

Type 

Wood burning stove

Trade name           

Contura 620T

Intended area of use 

Heating of rooms in residential buildings

Fuel 

Wood

MANUFACTURER

Name 

NIBE AB / Contura

Address 

Box 134, Skulptörvägen 10

 

SE-285 23 Markaryd, Sweden

VERIFICATION

According to AVCP 

System 3

European standard 

EN 13240:2001 / A2:2004 / AC:2007 

Test institute 

Rein-Ruhr Feuerstätten Prüfstelle, NB 1625. 

Declaration of performance according                                           

to Regulation (EU) 305/2011

DECLARED PERFORMANCE

ESSENTIAL CHARACTERISTICS

PERFORMANCE

HARMONISED TECHNICAL

SPECIFICATION

Fire safety

Pass

Fire classification

A1

Minimum distance to flammable 
materials

Rear: 

100 mm

Side: 

507 mm 

Ceiling:  810 mm
Front:  1200 mm
Floor:  0 mm
Corner:  100 mm

Fire hazard due to burning fuel falling out

Pass

EN 13240:2001 / A2:2004 / AC:2007

Cleanability

Pass

Emissions from combustion

CO: 

0,08%

Surface temperatures

Pass

Temperature on the handle

Pass

Mechanical resistance

Pass

Temperature in the space for wood storage 

Pass

Nominal output

6,0 kW

Efficiency

86,0%

Flue gas temperature at nominal output

206°C

Flue gas temperature in flue spigot

247°C

The undersigned is responsible for the manufacture and conformity with the declared performance.

Niklas Gunnarsson,

Business area manager NIBE STOVES

Markaryd, December 19, 2019

No. C620T-CPR-191219

Summary of Contents for C620T Style

Page 1: ...ve becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury Connection to chimney The stove must...

Page 2: ...rom floor to lower edge of hatch A separate glass hearth plate accessory increases the connection height to the chimney by 10 mm Permitted area for combustible parts of the building If the stove is placed on a hearth plate made of glass for example accessory the height from the floor is affected by a distance corresponding to the thickness of the hearth plate for a free standing glass hearth plate...

Page 3: ...e safety Pass Fire classification A1 Minimum distance to flammable materials Rear 100 mm Side 507 mm Ceiling 810 mm Front 1200 mm Floor 0 mm Corner 100 mm Fire hazard due to burning fuel falling out Pass EN 13240 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 0 08 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the space for w...

Page 4: ...s no room temperature control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection N...

Reviews: