background image

Rear Panel

1. 

LAN: 

Connect to an active network for LAN serving and Telnet and Web GUI 
control (refer to Sections on Telnet and Web GUI).
When the Matrix or any compatible LAN equipped receivers are connected 
to a network, this allows the network access (including internet access if 
available) to be shared between the Matrix and all connected receivers. 
Connect any Ethernet equipped device e.g. a Smart TV or games console 
to the LAN port of a receiver for that device to share the network/internet 
access.
Warning: Please do not connect more than one active Ethernet link within 
the Matrix system.

2. 

RS-232:

 

Connect to a PC or control system with D-Sub 9-pin cable for the 
transmission of RS-232 commands.

3. 

ALL IR OUT:

Connect to the IR blaster for IR signal transmission to the source side. 
Place the IR blaster in direct line-of-sight of the equipment to be controlled 
for it will blaster out all signal received from the IR IN at the receiver sides.

4. 

ALL IR IN:

Connect to the IR extender for IR signal reception. Ensure that remote 
being used is within the direct line-of-sight of the IR extender for it will send 
out the signal to all receiver's IR OUT.

5. 

SERVICE:

Manufacturer use only.

6. 

IR OUT 1~8:

Connect to the IR blasters for IR signal transmission. 
Place the IR blaster in direct line-of-sight of the equipment to be controlled 
for it will blaster out the IR signal received from the receiver side chosen by 
input selection.

7. 

IR IN 1~8:

Connect to the IR extenders for IR signal reception. Ensure that remote 
being used is within the direct line-of-sight of the IR extender for it will send 
out the IR signal to the selected receiver's IR OUT.

8. 

CAT5e/6/7 OUT 1~8:

Summary of Contents for 15437

Page 1: ...4K UHD Matrix 8 8 HDMI over HDBaseT with 24V PoC 15437 Operation Manual ...

Page 2: ...K2K 24 25 30 YUV_420 and 480i 1080p dependent upon the output display s EDID settings Supports distances up to 60 meters through CAT6 7 cables Supports 3D signal display dependent upon the output display EDID settings Supports PoC Power over Cable on compatible receivers only Supports HDMI input up to 15 meters at 8 bit resolution or 10 meters at 12 bit resolution Supports bi directional IR from i...

Page 3: ... all the buttons on the panel press again for 3 seconds to unlock The LED will illuminate green when locked 4 IR IR Receiver window accepts the remote control signal of this device only 5 MENU Press this button to access the LCM menu system from here EDID settings can be managed and IP system settings are displayed 6 1 8 A H and In Out Press the Out or In button to select the output or input mode ...

Page 4: ...blaster for IR signal transmission to the source side Place the IR blaster in direct line of sight of the equipment to be controlled for it will blaster out all signal received from the IR IN at the receiver sides 4 ALL IR IN Connect to the IR extender for IR signal reception Ensure that remote being used is within the direct line of sight of the IR extender for it will send out the signal to all ...

Page 5: ...y into the unit and connect the adapter to an AC outlet 11 PoC 24V Plug the 24 V PoC power supply into the unit and connect the adapter to an AC outlet This unit will power PoC Power over Cable capable receiver units Side Panel 1 Fan Ventilator These are air ventilation areas DO NOT block these areas or cover it with any object Please allow adequate space around the unit for air circulation Remote...

Page 6: ...t HDBaseT 8x8 Matrix Remote Control Pin Assignment Pin Assignment 1 N C 1 N C 2 Tx 2 Rx 3 Rx 3 Tx 4 N C 4 N C 5 GND 5 GND 6 N C 6 N C 7 N C 7 N C 8 N C 8 N C 9 N C 9 N C Baud Rate 19200 bps Data bit 8 bits Parity None Stop Bit 1 Flow Control None ...

Page 7: ...et GW Setting IP SubNet GateWay Static IP RSTIP IP Configuration Was Reset To Factory Defaults DHCP IPCONFIG Display the current IP config P0 Power OFF P1 Power ON I1 I8 Switch all the Output to 1 8 ST Display the current matrix status and F W version RS System Reset to A1 B2 C3 D4 E5 F6 G7 H8 EM Setting EDID MODE 1 STD 2 TV UARTBAUD1 8 Set output A D s uart baud rate from 1 6 1 9600bps 2 14400bps...

Page 8: ... by a carriage return Commands are case insensitive Telnet Control Before attempting to use the telnet control please ensure that both the Matrix via the LAN port and the PC Laptop are connected to the active networks To access the telnet control in Windows 7 click on the Start menu and type cmd in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd wi...

Page 9: ...ing us into the device which we wish to control Type HELP to list the available commands Type IPCONFIG To show all IP configurations To reset the IP type RSTIP and to use a set static IP type SETIP For a full list of commands see Telnet Commands Section Note Any commands will not be executed unless followed by a carriage return Commands are not case sensitive If the IP is changed then the IP Addre...

Page 10: ... status control and User setting pages Click on the Control tab to control power input output ports EDID and reset mode Clicking on the User Setting tab allows you to reset the IP configuration The system will ask for a reboot of the device every time any of the settings are changed The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entr...

Page 11: ...25 A DC US EU standards CE FCC UL certified ESD Protection Human Body model 8kV air gap discharge 4kV contact discharge Dimensions 438 mm W 249 mm D 93mm H Weight 4402g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 ºC 40 ºC 32 ºF 104 ºF Storage temperature 20 ºC 60 ºC 4 ºF 140 ºF Relative Humidity 20 90 RH no condensation Power Consumption 65 W Tx Main 56W Rx PoE ...

Page 12: ...Connection Diagram ...