2. To restart the valve, return the lever to its original horizontal position.
Removing the low profile water actuated valve lid
(See Figure 5 & 6)
It’s easy … Really! No tools needed!
You can disassemble the low-profile, water-actuated valve without the use of
tools. Follow these steps to remove the low-profile water activated valve.
1. Turn the pump off.
2. Loosen the clamp handle and remove the band clamp (2) from the
actuator valve.
3. Lift the clear lid from the actuator valve
and set aside on a clean surface.
Replacing the low profile water actuated
valve lid
1. Prior to replacing the lid, straighten and
clean the o-ring with clear water. Apply
a very thin film of non-petroleum based
lubricant if necessary.
2. Align both the hole in the top of the lid
with the stainless steel centre shaft and
the speed control guide with the grooved recess in the lid.
Place the tinted lid over
the lower housing and push gently down into position.
3. Install the band clamp and tighten the clamp handle only slightly.
Carefully alternate tapping around the perimeter of the band clamp while
re-tightening the clamp handle.
Tighten by hand only. Do not use any tools.
Page 5
FIGURE 5
PAUSE
RUN
2
2
FIGURE 6