MGRL/MGHL SERIES
04/08
2
SPECIFICATIONS
MOTOR
Type:
……………………… Restricted cycle duty
(25 cycles per day)
Horsepower:
……………… 1/3hp, 1/2 hp
Speed:
…………………….. 1700 RPM
Voltage:
…………………… 115, 230 – 1 phase
208/230, 460 – 3 phase
230 volt 3 phase motor is suitable for use with 208 volts
Current:
………………….. See motor nameplate
ELECTRICAL
Transformer:
…………….. 24VAC
Wiring Type:
…………….. Momentary pressure open, stop, constant pressure close
(provided standard), with provision for momentary
pressure close*
Limit Adjustment:
………. Linear driven, fully adjustable screw type cams.
MECHANICAL
Drive reduction:
…………. 43:1
Output shaft speed:
……... 40 RPM
Door Speed:
………………. 6 - 9” per sec. average (typical)
Brake:
…………………….. Solenoid actuated brake
Release Mechanism:
……... Floor level pull-cable release standard
Emergency Chain
Hoist:
.... Optional
(Standard on MGHL)
ENTRAPMENT PROTECTION
Sensing Edge*:
…………… (Optional) Sensing device attached to the bottom edge of
the door.
* Per the requirements of UL Standard 325, the door operator must be provided with an
actuating device requiring constant pressure to close the door. As an alternative, the door
may be provided with a device that will reverse the door upon contact with an obstruction
during closing.
Summary of Contents for MGHL Series
Page 13: ...12 MGRL MGHL SERIES 04 08...
Page 14: ...MGRL MGHL SERIES 04 08 13...
Page 15: ...MGRL MGHL SERIES 04 08 14...
Page 16: ...MGRL MGHL SERIES 04 08 15...
Page 17: ...MGRL MGHL SERIES 04 08 16...
Page 18: ...MGRL MGHL SERIES 04 08 17...
Page 19: ...MGRL MGHL SERIES 04 08 18...
Page 20: ...MGRL MGHL SERIES 04 08 19...