background image

●  The number of PM2.5 particles, air quality status, and machine intelligently running status as below.

Smart setting

●  PM2.5 Sensor built-in.

●  Air quality indicator will be lighted after pressing the “Smart” icon on the product operating panel , the machine will check 

   the air quality and control its working status automatically.

●  PM2.5 sensor: it's to check the dust or particles and display it by data.The diagram as following:

OPERATING INSTRUCTION

11

12

User manual

OPERATING INSTRUCTION

 

 

PM2.5 abnormal correcting

After used the PM2.5 sensor for a long time, trace amounts of particulate will adhere to the sensor inductive head, it may cause the PM2.5 

numerical display abnormal.When you find PM2.5 numerical severly deviated from the normal range, here we advise you collect it as follow 

steps based on the weather forecast's PM2.5 numerical in your city.

1.Open the window ventilated for 5 minutes(PM2.5 sensor will re-collection current environmental data).

2.Long press "function" icon, after heard a "click", showing it antomatic switch to PM2.5 display window, then enter PM2.5 correcting mode.

3

3.Each time you press "function" icon, the machine's PM2.5 numerical will increase 2ug/m , each time you press "smart" icon,

3

PM2.5 numerical will decrease 2ug/m .

4.When the PM2.5 numerical adjust to the PM2.5 numerical of your city's weather forecast,waiting 5 seconds

PM2.5 sensor collection finished. 

Reset setting

●  If the filter icons are always flashing, it means the filters life time comes to the end, please clean or replace new filters.

●  After cleaning or replacing new filters, please press “Reset”icon, then filter icons will stop flashing, the machine starts 

   to record the filters using time.

Remark :”Reset” icon has refresh function,PM2.5 data can be refreshed after pressing the “ Reset” icon on the product operating panel .

Refresh setting

 

 

Press " refresh" button to refresh PM2.5 value.

Remarks 1:

The three smart light on the top is stand for air quality.

Remarks 2:

when

 

you

 

choose

"

Smart

mode

the

 

device

 

will

 

take

 

3

 

minutes

 

to

 

warm

 

up

, "

function

icon

 

can

 

not

 

use

 

in

 

this

 

mode

.

Remarks 3:

 

when

 

air

 

humidity

 

is

 

above

 

80

%, 

it

 

will

 

affect

 

the

 

sensitivity of

 

sensor

the

 

PM2

.

5

 

data

 

is

 

just

 

for

 

your

 

reference

Timer

Smart

Speed

Function

Reset

%

Timer

Smart

Speed

Function

Reset

%

Excellent 

Green light 

Slight, medium pollution 

Orange

Serious pollution

Red light 

Timer

Smart

Speed

Function

Reset

%

Timer

Smart

Speed

Function

Reset

%

Timer

Smart

Speed

Function

Reset

%

Filter replacement indicator

HEPA

Activated Photo Catalyst

 

Washable Pre-filter

Smart air purifier

Air quality 

indicator color

PM2.5

Green light 

Level

 

1

3

35ug

/

m

Orange light 

Level

 

3

3

36

-

150ug

/

m

Level

 

5

3

151ug

/

m

Red light 

Speed

 

Summary of Contents for B-C02

Page 1: ...r instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Attention If the parameter specific...

Page 2: ...ommercial Use Smart air purifier 3 2 1 3 CAUTIONS WARNING ATTENTION 4 4 4 PRODUCT PERFORMANCE AND TECHNICAL FEATURES Product performance Technical features 5 6 6 5 5 COMPONENT INTRODUCTION Diagram of the outlook Diagram of unit Operating parts 7 8 CAUTIONS BEFORE OPERATING 7 How to touch the control panel 8 Placement 7 Disassembling front cover 8 Installation of the filters 8 Power supply 9 9 10 1...

Page 3: ...insulation even cause fire Take out the plug and clean it with dry cloth Please remove the plug from the socket if not using for a long period AVOID WET Avoid any water on the surface of the unit It may cause short circuit or electrical shocking DISCONNECT POWER Do not insert any metal objects into the unit It may cause hurt or electric shocking WARNING FORBID Do not use the over run socket or wir...

Page 4: ...hnical features PRODUCT PERFORMANCE AND TECHNICAL FEATURES FORBID Do not use in the room with lampblack such as kitchen It may cause hurt because the machine is not a ventilator Please ventilate timely when used with fire in the room Otherwise it may cause poisoning of Co as the machine is not a 1 ventilator Do not power the unit on when using insecticide in the room Otherwise the insecticide may ...

Page 5: ...er manual Front View Air outlet Front Cover Air In Air In IMD Control Panel PM2 5 Sensor Back Cover Cable hole Back View UV lamp Anion d e e p s t s e h g i H S l e e p m o d e Timer Smart Speed Function Reset Filter replacement indicator Function Display Power on off Activated Carbon Photo Catalyst Main Body UV lamp HEPA Front cover Washable Pre filter Smart air purifier ...

Page 6: ...parent bags and put them back into device accordingly CAUTIONS BEFORE OPERATING Please keep the machine air inlet and outlet 30cm or more away from the wall and home furniture Do not use the machine in front of heat source outlet Disassembling front cover Disassembling diagram Disassembling diagram Installation diagram Insert two pins of bottom side into two slot of main body Hold on the front cov...

Page 7: ...eed and noise are very low all indicators are not lighted OPERATING INSTRUCTION OPERATING INSTRUCTION 9 Anion UV lamp Long press Timer icon the displayed digit is flashing then the timer mode is started Press Timer icon continuously the time can be chosen from 0 to 12 hours the device memory function will be started after waiting for 5 seconds The diagram as following Remark 1 Press time button on...

Page 8: ...ecrease 2ug m 4 When the PM2 5 numerical adjust to the PM2 5 numerical of your city s weather forecast waiting 5 seconds PM2 5 sensor collection finished Reset setting If the filter icons are always flashing it means the filters life time comes to the end please clean or replace new filters After cleaning or replacing new filters please press Reset icon then filter icons will stop flashing the mac...

Page 9: ...the unit with the solvent listed on the right which may cause distortion or discolour Please remove plug from the socket before cleaning and maintenance Decontamination power Alkalescence Benzene Acohol Scour Maintenance and cleaning instruction Hold the UV lamp and rotate it for 90 clockwise or anticlockwise then take it out Hold the UV lamp and rotate it for 90 clockwise or anticlockwise then in...

Page 10: ... Does the using life time for activated carbon filter come to the end Please replace new filters High noise Small changes for humidity or temperature data Is the machine using area too big Please use this machine in applicable room Air quality indicator can not work properly Is the air humidity very high Is the machine affected by kitchen oil fume or sprays Please move the machine to another room ...

Reviews: