E l e c t r i c a l S p e c i f i c a t i o n s
Important –
Qualified and licensed electricians must perform all
electrical hookups. The following specifications must be followed in
order to ensure proper performance and safety.
WARNING:
Starting an incorrectly wired spa could cause
severe damage to the mechanical equipment or
even bodily harm. Have your licensed electrician
verify GFCI (or RCD) wiring with the schematics on
pages 9-10 prior to starting the spa or call the
technical support line at (727) 490-2239.
Caution:
Failure to abide by specifications listed may result in
damage to the equipment and will void the warranty.
US/Canada:
All spas must be wired with a GFCI breaker in the service panel
(see table below for proper sizing). Failure to do so will cause
equipment damage and will not be covered under your warranty.
Model
Volts Freq.
Rating
Amps
GFCI
Amps
Wire size
Controller
Domestic
CN 8000, CN 9000, CN 10000
240
60
40
50
6-3 plus ground VS510SZ
Domestic
CN 7000
240
60
40
50
6-3 plus ground
VS501Z
Europe
CN 8000, CN 9000, CN 10000
220-240 50
1x32
or 2x16
IEE wire
regulation
3 or 5 Wires 4mm² GS510Z
Europe
CN 7000
220-240 50
1x32
or 2x16
IEE wire
regulation
3 or 5 Wires 4mm² GS501Z
CN 3000
240
60
32
40
6-3 plus ground
VS500Z
EUROPE:
WARNING:
Disconnect the electrical power before servicing.
Before obtaining access to terminals, all supply
circuits must be disconnected.
Avertissement:
Disconnecter du circuit d'alimentation
electrique avent l'entretien.
Summary of Contents for CN 10000
Page 12: ...10 240V Wiring All wiring is 6 3 plus ground solid copper ...
Page 14: ...12 For CN 7000 Domestic model For CN 7000 European Model ...
Page 15: ...13 For CN 3000 Domestic Models ...
Page 22: ...20 ...
Page 35: ...33 Notes ...
Page 46: ...44 Notes ...
Page 47: ...45 Notes ...
Page 50: ...48 Notes ...
Page 52: ...5301 E Hanna Ave Tampa FL 33610 727 490 2239 www CoolNightsSpas com ...