3
Output
Voltage
Range
MIN
NOM
MAX
Unit
+5V
+12V
-5V
-12V
+3.3V
+5Vsb
±
5%
+4.75
+11.40
-4.50
-10.80
+3.14
+4.75
+5.00
+12.00
-5.00
-12.00
+3.30
+5.00
+5.00
+12.60
-5.50
-13.20
+3.47
+5.25
Volts
Volts
Volts
Volts
Volts
Volts
±
5%
±
10%
±
5%
±
5%
±
10%
4. Output
4.1. Output Regulations
Note: The output voltage should be measured at the terminals of output
connector.
4.2. Power Distribution Configuration
4.3. Cross Regulation
The DC loads shall remain within the ranges specified in 4.2 Power
Distribution Configuration and the DC output voltages also shall remain
within the regulation ranges specified in 4.1 Output Regulations when
measured at the load end of the output connectors.
+3.3V
+5V
+12V
-5V
-12V
+5Vsb
Max. 350W
FL-350ATX
(CF-350)
FL-420ATX
(CF-400)
FL-480ATX
(CF-480)
Max. 400W
Max. 480W
28A
35A
15A
0.5A
0.8A
2.5A
Max. 300W
FL-550ATX
(CF-300)
25A
30A
15A
0.3A
0.8A
2A
30A
18A
1A
1A
2.5A
30A
45A
18A
1A
1A
2.5A
40A
Output
Rail
Cable
Color
Orange
Red
Yellow
White
Blue
Purple
Summary of Contents for CF-300