3.4.5 Over Power Protection
When the total load exceed 110%~160% of the maximum output current, the
power supply shall be latched into the state of shutdown.
Operation Conditions
The power supply shall be capable of continuous operation and meet all
electrical specification without need for adjustment when subjected to the
following environmental conditions:
Temp. Vs Load Condition
Humidity
Operation
Storage
-20C ~80C
10% ~90%RH
5% ~90%RH
No degradation of the power supply shall occur during shipping or storage at
the specified condition.
3.6 Regulatory Compliance
Caution: Unauthorized personnel should not do this to avoid electrical
shock!
4.1 Do not open the top cover of the power supply case.
4.2 Please keep the power supply from humidity.
0 ~30C@Full Load
40C@90% Rated Load
50C@80% Rated Load
3.5 Physical Environment
4
Our power supply has been certified to comply with multi-national Safety and EMI.
TUV, UL, CUL, CSA, CE, FCC
4. Precaution