background image

3.4.5 Over  Power Protection

When the total load exceed 110%~160% of the maximum output current, the 
power supply shall be latched into the state of shutdown.                      

Operation Conditions

The power supply shall be capable of continuous operation and meet all 
electrical specification without need for adjustment when subjected to the 
following environmental conditions:

Temp. Vs Load  Condition

Humidity

Operation

Storage

-20C ~80C

10% ~90%RH

5% ~90%RH

No degradation of the power supply shall occur during shipping or storage at 
the specified condition.     

3.6 Regulatory Compliance 

 

Caution: Unauthorized personnel should not do this to avoid electrical  

shock! 

4.1 Do not open the top cover of the power supply case.

4.2 Please keep the power supply from humidity.

0 ~30C@Full Load

40C@90% Rated Load

50C@80% Rated Load

3.5 Physical Environment 

4

Our power supply has been certified to comply with multi-national Safety and EMI.

TUV, UL, CUL, CSA, CE, FCC

4. Precaution 

Summary of Contents for CTG-750

Page 1: ...Table of Content 1 Function Description 2 How to Setup 3 Specifications 4 Precaution 5 Simple Maintainance 6 Mechanical Diagram 1 4 5 1 5 1 ...

Page 2: ...Connector dual PCI express power connector Peripheral Connectors and Floppy Connectors to the corresponding male connectors of main board peripheral devices i e HDD CDROM etc and floppy drivers respectively When you connect connectors please pay attention to the orientation of them because of the different hole sizes Find the proper orientation and push down firmly making sure that the pins are al...

Page 3: ... 5A 3 0A Load range 2 AC 230V APE 1100X CTG 1000 APE 1100X CTG 1000 30A 50A 19A 19A 19A 19A 0 5A 3 0A 30A 40A 19A 19A 19A 19A 0 5A 3 0A 3 2 Active Power Factor Correction Active power factor correction the advance technology most used in high power SMPS used a per regulator before the main PWM convert circuit applied the current feedback technology Regulated current drawing flow AC sinusoidal wave...

Page 4: ...t no damage can occur to the power supply All outputs shall be protected so that on damage occurs to the power supply under shorted output condition Voltage Over Current Limit 3 3V 5V 12V 110 minimum 150 maximum 110 minimum 150 maximum 110 minimum 150 maximum 3 4 4 240VA Protection System designs may require user access to energized areas of the system In these cases the power supply may be requir...

Page 5: ...Load Condition Humidity Operation Storage 20C 80C 10 90 RH 5 90 RH No degradation of the power supply shall occur during shipping or storage at the specified condition 3 6 Regulatory Compliance Caution Unauthorized personnel should not do this to avoid electrical shock 4 1 Do not open the top cover of the power supply case 4 2 Please keep the power supply from humidity 0 30C Full Load 40C 90 Rated...

Page 6: ...ction please send it back to your retailer or distributor for repair 6 1 Power Connector Drawing 6 Mechanical Diagram 5 Main Power Connector Peripheral Power Connector Floppy Power Connector 5VDC COM COM 12V4DC Pin 1 Pin 4 12VDC COM COM 5VDC Pin 1 Pin 4 12V Power Connector 12VDC 12VDC COM COM Pin 3 Pin 1 Pin side view not to scale Serial ATA Connector 3 3VDC COM 5VDC 12VDC 3 3VDC 3 3VDC COM COM 5V...

Page 7: ...C Black GND Red 5VDC Black GND Orange 3 3VDC SATA 12V 4P Black GND 1 4 Yellow Green 12V4DC 3 Yellow Green 12V4DC Black GND 2 4 Black GND 5 Black GND 6 Black GND PCI E Yellow Green 12V4DC 1 Yellow Green 12V4DC 2 Yellow Green 12V4DC 3 Black GND 1 5 Yellow Black 12V1DC 8P Black GND 2 Black GND 3 Black GND 4 6 Yellow Black 12V1DC 7 Yellow 12V2DC 8 Yellow 12V2DC PRELIMINARY REV 1 MATERIAL TOLERANCE DRA...