background image

 

 

3.3.3 Over Load Protection  

When the total load exceed 130%~160% of the maximum output current, the power 
supply shall be latched into the state of shutdown.  

3.4 Physical Environment  

Operation Conditions  

The    power    supply    shall    be    capable    of    continuous    operation    and    meet    all 
electrical    specification    without    need    for    adjustment    when    subjected    to    the 
following environ-mental conditions:  

 

Temp. Vs Load Condition 

Humidity 

0 ~30C@Full Load  

Operation 

-20C ~80C@90% Rated Load 

10% ~90%RH 

-20C ~80C@80@ Rated Load  

Storage 

-20C ~80C 

5% ~90%RH 

 

No  degradation  of  the  power  supply  shall  occur  during  shipping  or  storage  at  the 
specified condition.  

3.5 Regulatory Compliance  

 

Our  power  supply  has  been  certified  to  comply  with  multi-national  Safety  and  
EMI.  

-- UL, CUL, CSA, TUV, FCC, CB  

4. Precaution  

Caution:  Unauthorized  personnel  should  not  do  this  to  avoid  electrical  
 

shock!  

4.1 Do not open the top cover of the power supply case.  

 

4.2 Please keep the power supply from humidity.  

5. Simple Maintenance  

 

If  power  supply  cannot  work  properly,  before  send  for  repair,  please  check  the 
following items:  

5.1 Does power cord indeed plug into electrical outlet?  

 
 
 
 

3  

Summary of Contents for V-400

Page 1: ...is power supply to your precious computer tower Follow the steps below to finish the setup Step1 Open the computer tower cover put the power supply into the corresponding location of the tower and then use right screws to fix the power supply to tower Step2 Put the Main Power Connector ATX12V Connector S ATA Connector Peripheral Connectors and Floppy Connectors to the corresponding male connectors...

Page 2: ...ion functions described as below 3 3 1 Short Circuit Protection A short circuit on any DC output will cause the power to latch The power supply will withstand a continuous short circuit to the output without damage or overseers to the unit The 5VSB can be shorted indefinitely and will recover automatically when the short is removed 3 3 2 No Load Operation No hazardous conditions or damage to the s...

Page 3: ...ed Load 10 90 RH 20C 80C 80 Rated Load Storage 20C 80C 5 90 RH No degradation of the power supply shall occur during shipping or storage at the specified condition 3 5 Regulatory Compliance Our power supply has been certified to comply with multi national Safety and EMI UL CUL CSA TUV FCC CB 4 Precaution Caution Unauthorized personnel should not do this to avoid electrical shock 4 1 Do not open th...

Page 4: ... output connectors plugging in proper direction and connecting firmly 5 4 Please turn off the power and turn it on for several times and the interval must be at least 5 seconds 5 5 Having checked above items if the power supply still does not function please send it back to your retailer or distributor for repair ...

Reviews: