C200H AC Servo Manual
102
No.
Alarm
name
Running state
Reason
Processing method
3
Main
circuit
undervolt
age
Appears when
the main
power is
turned on
1. Circuit board failure.
2. The power fuse is
damaged.
3. Soft start circuit failure.
4. The rectifier is damaged.
Replace the servo driver.
1. The power supply
voltage is low.
2. Temporary power
failure for more than 20ms.
Check the power supply.
Appears
during motor
operation
1. Insufficient power
capacity.
2. Instantaneous power
failure.
Check the power supply.
The radiator is overheating.
Check the load condition.